{"product_id":"frost-fighter-48807-6-inch-flue-pipe-extension-3-ft","title":"Frost Fighter 48807 Flue Pipe Extension 3 ft, 6 in. Galvanized, No Cap, for IDF and IDH Heaters","description":"\u003ch2\u003eFlue Pipe Extension That Adds the 3 ft of Vertical Run Frost Fighter's Manual Calls For\u003c\/h2\u003e\n\u003cp\u003eThe flue collar on a Frost Fighter IDF or IDH heater is short. The manual requires the flue to end in a vertical section at least 2 ft long, and calls a 36 in. extension before the rain cap highly advisable. The \u003cstrong\u003eFrost Fighter 48807 Flue Pipe Extension\u003c\/strong\u003e is that pipe: 3 ft of 6 in. galvanized flue pipe, sold without a cap.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features and Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eThe Frost Fighter flue pipe extension provides the 36 in. of pipe before the rain cap that the IDF manual calls highly advisable for outdoor use.\u003c\/li\u003e\n  \u003cli\u003eGalvanized single-wall steel with one crimped end that nests into the heater's 6 inch flue pipe collar or the next pipe section. The open end fastens onto the heater's flue.\u003c\/li\u003e\n  \u003cli\u003eThe 6 in. diameter matches every Frost Fighter IDF and IDH heater. No adapter or reducer is needed.\u003c\/li\u003e\n  \u003cli\u003eSold without a cap, this Frost Fighter flue pipe extension suits a buyer who already owns a 48808 vent cap or needs a replacement pipe only.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003ePipe, Cap, or Both\u003c\/h2\u003e\n\u003cp\u003eFour Frost Fighter heater parts cover the flue, and each serves a different purpose. If you need the pipe and cap as one chimney pipe extension, the 48809A ships with the rain cap already attached. The 48807 is pipe only, paired with a separate 48808 vent cap.\u003c\/p\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"col\"\u003e\u003cstrong\u003ePart\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth scope=\"col\"\u003e\u003cstrong\u003eWhat It Is\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth scope=\"col\"\u003e\u003cstrong\u003eCap Included\u003c\/strong\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e\u003cstrong\u003e48807\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003e3 ft galvanized flue pipe, 6 in.\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd\u003e\u003cstrong\u003eNo\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e48808\u003c\/td\u003e\n      \u003ctd\u003eRain and vent cap, 6 in.\u003c\/td\u003e\n      \u003ctd\u003eCap only\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e48809A\u003c\/td\u003e\n      \u003ctd\u003e3 ft flue pipe with 6 in. rain vent cap\u003c\/td\u003e\n      \u003ctd\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003e78809A\u003c\/td\u003e\n      \u003ctd\u003e3 ft flue pipe with 8 in. rain cap\u003c\/td\u003e\n      \u003ctd\u003eYes, IHS700 only\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eHow It Fits\u003c\/h2\u003e\n\u003cp\u003eFrost Fighter's IDF manual gives a two-step instruction for the Frost Fighter flue pipe extension. First, fasten the rain cap on the end of the 3 ft pipe. Then fasten the open end onto the heater's flue collar. Joints must be tight. The pipe cross-section must not be smaller than the flue collar. Horizontal runs rise 1 in 10 away from the heater, and no elbow may exceed 90 degrees.\u003c\/p\u003e\n\n\u003ch2\u003eWhich Heaters Use It\u003c\/h2\u003e\n\u003cp\u003eThis flue pipe extension fits every Frost Fighter heater with a 6 in. flue. Frost Fighter's manuals give a 6-inch flue pipe on the \u003ca href=\"https:\/\/cleanflow.net\/products\/frost-fighter-idf350-indirect-fired-heater-350-000-btu-h\"\u003eIDF350\u003c\/a\u003e, \u003ca href=\"https:\/\/cleanflow.net\/products\/frost-fighter-idf500-indirect-fired-portable-heater-420-000-btu-h-dual-fuel-50-ft-ducting-capability-csa-etl-certified-industrial-grade\"\u003eIDF500\u003c\/a\u003e, \u003ca href=\"https:\/\/cleanflow.net\/products\/frost-fighter-indirect-oil-diesel-fired-heater-170-000-btu-h\"\u003eIDH200QR\u003c\/a\u003e, IDH350QR, \u003ca href=\"https:\/\/cleanflow.net\/products\/frost-fighter-idh400qr-indirect-fired-heater-400-000-btu-h\"\u003eIDH400QR\u003c\/a\u003e, and \u003ca href=\"https:\/\/cleanflow.net\/products\/frost-fighter-indirect-oil-diesel-fired-heater-500-000-btu-h\"\u003eIDH500QR\u003c\/a\u003e. It does not fit the IHS series, which vents at 8 in.; the \u003ca href=\"https:\/\/cleanflow.net\/products\/frost-fighter-ihs700h-dual-fuel-indirect-fired-heater-700-000-btu-8000-cfm-csa-certified\"\u003eIHS700H\u003c\/a\u003e and \u003ca href=\"https:\/\/cleanflow.net\/products\/frost-fighter-ihs700p-dual-fuel-indirect-fired-heater-700-000-btu\"\u003eIHS700P\u003c\/a\u003e take the \u003cstrong\u003e78809A\u003c\/strong\u003e. DF direct-fired heaters have no flue.\u003c\/p\u003e\n\n\u003ch2\u003eFrost Fighter 48807 Flue Pipe Extension Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth scope=\"col\"\u003e\u003cstrong\u003eSpec\u003c\/strong\u003e\u003c\/th\u003e\n      \u003cth scope=\"col\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFrost Fighter Part\u003c\/td\u003e\n      \u003ctd\u003e48807\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eType\u003c\/td\u003e\n      \u003ctd\u003eSingle-wall galvanized flue pipe\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaterial\u003c\/td\u003e\n      \u003ctd\u003eGalvanized steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDiameter\u003c\/td\u003e\n      \u003ctd\u003e6 in.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLength\u003c\/td\u003e\n      \u003ctd\u003e3 ft (36 in.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCap Included\u003c\/td\u003e\n      \u003ctd\u003eNo (order 48808 separately)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n      \u003ctd\u003e24 in.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFits\u003c\/td\u003e\n      \u003ctd\u003eAny Frost Fighter heater with a 6 in. flue (IDF and IDH series)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eNot For\u003c\/td\u003e\n      \u003ctd\u003e8 in. flues (IHS700); DF direct-fired heaters (no flue)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRelated Parts\u003c\/td\u003e\n      \u003ctd\u003e48808 vent cap; 48808A storage cap; 48809A 3 ft extension with cap; 78809A 8 in. version\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eBuy Flue Pipe Extension Online from Cleanflow\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCleanflow Utility Supply Company\u003c\/strong\u003e is an authorized Frost Fighter dealer and stocks this flue pipe extension with the \u003ca href=\"https:\/\/cleanflow.net\/collections\/frost-fighter\"\u003eFrost Fighter heaters and accessories\u003c\/a\u003e it fits and other Frost Fighter heater parts. Free shipping on orders over $199. Returns accepted within 30 days; email \u003ca href=\"mailto:info@cleanflow.ca\"\u003einfo@cleanflow.ca\u003c\/a\u003e. Ships across Canada and the USA. Call 1-866-335-1078 for heater flue pipe questions.\u003c\/p\u003e\n\n\u003cdiv itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\n  \u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n  \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n    \u003ch3 itemprop=\"name\"\u003eCan you extend a flue pipe on a Frost Fighter heater?\u003c\/h3\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cdiv itemprop=\"text\"\u003e\n        \u003cp\u003eYes. Frost Fighter flue pipe extension 48807 adds 3 ft to IDF and IDH heater flues. The IDF manual calls the 36 in. length before the rain cap highly advisable for outdoor installations.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n    \u003ch3 itemprop=\"name\"\u003eHow to extend a flue pipe on a Frost Fighter indirect-fired heater?\u003c\/h3\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cdiv itemprop=\"text\"\u003e\n        \u003cp\u003eFrost Fighter's manual gives two steps. Fasten the rain cap on the end of the 3 ft heater flue pipe. Then fasten the open end of the pipe onto the flue collar. Joints must be tight and securely attached.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n    \u003ch3 itemprop=\"name\"\u003eWhich end of stove pipe goes up when installing a flue extension?\u003c\/h3\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cdiv itemprop=\"text\"\u003e\n        \u003cp\u003eOn the 48807, one end is crimped, and the other is plain. The crimped end nests into the next section or collar. Frost Fighter's manual says to fasten the open end of the pipe onto the flue of the unit.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n    \u003ch3 itemprop=\"name\"\u003eIs the 48807 a flue pipe extension kit?\u003c\/h3\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cdiv itemprop=\"text\"\u003e\n        \u003cp\u003eNo. The 48807 is pipe only, with no cap. For a flue pipe extension kit with the rain cap, order the 48809A chimney pipe extension. Buying a 48807 and a 48808 cap separately covers the same need.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n    \u003ch3 itemprop=\"name\"\u003eWhat is the single wall flue pipe clearance on a Frost Fighter heater?\u003c\/h3\u003e\n    \u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n      \u003cdiv itemprop=\"text\"\u003e\n        \u003cp\u003eFrost Fighter's manuals require 24 in. of clearance from the flue pipe to combustible materials. This applies to the 48807 galvanized flue pipe and to the flue connector on every IDF and IDH unit.\u003c\/p\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Frost Fighter","offers":[{"title":"Default Title","offer_id":67732592132460,"sku":"48807","price":87.5,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/Frost_Fighter_48807_Flue_Pipe_Extension_3_ft_6_in...webp?v=1792495214","url":"https:\/\/cleanflow.net\/products\/frost-fighter-48807-6-inch-flue-pipe-extension-3-ft","provider":"Cleanflow","version":"1.0","type":"link"}