{"product_id":"fwme-1812","title":"Franklin FWME 1812 Residential Reverse Osmosis Membrane","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003e1812 RO Membrane Replacement for 50–100 GPD Under-Sink Systems\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYour under-sink RO system's membrane wears out every 2 to 3 years. When water output drops or your TDS meter reads higher than usual, the \u003c\/span\u003e\u003cspan\u003eFranklin Water FWME 1812 reverse osmosis membrane\u003c\/span\u003e\u003cspan\u003e fits standard 2\" x 12\" residential housings as a direct replacement. Available in 50, 75, and 100 GPD with 95-96% salt rejection. Tested at 60-75 psi with 500 mg\/L feed solution and rated for feed water up to 1,000 mg\/L TDS. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCleanflow Utility Supply Company\u003c\/span\u003e\u003cspan\u003e is an authorized Franklin Water Treatment distributor shipping across Canada and the USA.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eQuick Specs\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003eMembrane Type\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e Thin-Film Composite (TFC), Aromatic Polyamide\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003eElement Size\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e 1.8\" x 12\" (standard 1812 format)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003eAvailable GPD\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e: \u003c\/strong\u003e50 (FWME1812RO50), 75 (FWME1812RO75), 100 (FWME1812RO100)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003eSalt Rejection\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e: \u003c\/strong\u003e95-96% (Method A), 98-98.5% (Method B)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003eTest Pressure\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e 60 psi (50\/75 GPD), 75 psi (100 GPD)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003eMaximum Operating Pressure\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e: \u003c\/strong\u003e300 psi (2.07 MPa)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003eOptimal Feed TDS\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e up to 1,000 mg\/L (max rated: 2,000 mg\/L)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e: \u003c\/strong\u003eNSF\/ANSI 61\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eKey Features and Benefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eDirect residential RO membrane replacement that fits most under-sink systems, water coolers, and beverage equipment in the standard 1812 format without adapters or housing changes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eAvailable as a 50 GPD, 75 GPD, or 100 GPD RO membrane to match your household water demand, from a single drinking faucet up to a full kitchen with ice maker and refrigerator line.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eFits standard 2\" x 12\" membrane housings used in most under-sink RO membrane systems sold across North America, no modifications or adapters needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eBuilt with aromatic polyamide thin-film composite (TFC) construction, the same TFC reverse osmosis membrane technology your original element uses, so the replacement performs the same way.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eNSF\/ANSI 61 certified as a drinking water RO membrane, confirming it meets health-effects requirements for drinking water contact. Cleanflow also carries other Franklin Water \u003c\/span\u003e\u003ca href=\"https:\/\/cleanflow.net\/collections\/reverse-osmosis-membranes\"\u003e\u003cspan\u003ereverse osmosis membranes\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e in the Franklin Water lineup.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003e95-96% salt rejection (Method A) on feed water up to 1,000 mg\/L TDS, a reliable point-of-use RO membrane for municipal tap water and low-TDS well water.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"text-align: -webkit-left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/Franklin_reverse_osmosis_membrane_overview.png?v=1783295028\" alt=\"Franklin reverse osmosis membrane overview\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cp dir=\"ltr\"\u003e \u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eFWME 1812 Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv align=\"left\" dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"240\"\u003e\n\u003ccol width=\"400\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFranklin Water Treatment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel Series\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFWME 1812\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eAvailable Models\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFWME1812RO50, FWME1812RO75, FWME1812RO100\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMembrane Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThin-Film Composite (TFC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMembrane Material\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAromatic Polyamide\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eElement Size\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1.8\" x 12\" (1812 standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eActive Area (50\/75 GPD)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e4.2 ft² \/ 0.39 m²\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eActive Area (100 GPD)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e6.3 ft² \/ 0.59 m²\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePermeate: FWME1812RO50\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e50 GPD \/ 0.19 m³\/d\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePermeate: FWME1812RO75\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e75 GPD \/ 0.28 m³\/d*\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePermeate: FWME1812RO100\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e100 GPD \/ 0.38 m³\/d\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSalt Rejection (Method A)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e96% (RO50); 95% (RO75, RO100)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSalt Rejection (Method B)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e98.5% (RO50); 98% (RO75, RO100)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMaximum Operating Pressure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e300 psi \/ 2.07 MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTest Pressure (Method A)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e60 psi (50\/75 GPD); 75 psi (100 GPD)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTest Solution (Method A)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e500 mg\/L (NaHCO3, CaCl2, MgSO4)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTest Solution (Method B)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e250 mg\/L NaCl\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTest Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e25°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTest Recovery (Method A)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e55%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTest Recovery (Method B)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e20-30%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eOptimal Feed TDS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eUp to 1,000 mg\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMaximum Feed TDS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e2,000 mg\/L (per Key Operating Summary)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMaximum Feed SDI\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e5\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eFeed Chlorine Tolerance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u0026lt;0.1 mg\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003epH Range (Continuous)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e3 to 10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003epH Range (Cleaning)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e2 to 12\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e0 to 45°C (32 to 113°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNSF\/ANSI 61\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTypical Feed Water Sources\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMunicipal Water, Groundwater, Surface Water, Residential Well Water\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eUnder-sink residential reverse osmosis drinking water systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eOffice and breakroom point-of-use water filtration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eWater coolers, ice makers, and refrigerator water line filtration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eCoffee, tea, and beverage preparation equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eSmall-capacity water vending and self-serve refill stations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003ePrivate well water treatment for homes on groundwater\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eAquarium and hydroponic water preparation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eIndustries\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eResidential water treatment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eCommercial food and beverage service\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eOffice and facility management\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eAquaculture and horticulture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eBuy the Franklin Water FWME 1812 Reverse Osmosis Membrane Online from Cleanflow\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWhen your under-sink membrane needs replacing, the FWME 1812 is the home RO membrane replacement that fits standard residential housings in 50, 75, or 100 GPD. This 1812 reverse osmosis membrane carries NSF\/ANSI 61 certification and drops into most systems without modifications. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe FWME 1812 reverse osmosis membrane, compatible \u003c\/span\u003e\u003ca href=\"https:\/\/cleanflow.net\/collections\/reverse-osmosis-system-accessories\"\u003e\u003cspan\u003ereverse osmosis system accessories\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, and replacement filters ship across Canada and the USA. Returns accepted within 30 days at returns.cleanflow.net.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhat size membrane fits my under-sink RO system?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMost residential under-sink RO systems use a standard 1812 RO membrane, which measures 1.8 inches in diameter and 12 inches long. The Franklin Water 1812 membrane fits this standard housing. Check your existing membrane for the size printed on the label before ordering. If your system uses a different size like 2012 or 1812-75, the FWME 1812 series covers those as well.\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eHow often should I replace my RO membrane?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMost residential RO membranes last 2 to 3 years under normal use. Replace the Franklin Water FWME 1812 reverse osmosis membrane sooner if you notice water output slowing down, if your TDS meter shows higher readings than when the membrane was new, or if the water starts tasting different. Heavy use or high-TDS well water can shorten membrane life.\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhat is the difference between the 50, 75, and 100 GPD models?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eGPD means gallons per day, the amount of filtered water the membrane produces under test conditions. The 50 GPD model fills a storage tank more slowly but works fine for a single drinking faucet. The 75 and 100 GPD models fill faster and suit households that also run an ice maker or refrigerator water line. All three fit the same housing. Choose the Franklin Water residential RO membrane that matches the GPD rating printed on your current element.\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eCan I use the FWME 1812 on well water?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes, if your well water TDS stays below 1,000 mg\/L (the membrane is rated up to 2,000 mg\/L maximum). Get a water test first. If your well water has high iron, manganese, or hydrogen sulfide, you need pre-treatment (a sediment filter and possibly an iron filter) before the RO system. This thin-film composite membrane 1812 cannot tolerate chlorine above 0.1 mg\/L, but most well water is untreated and chlorine-free.\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhat pre-treatment does my home RO system need?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAt minimum, your RO system should have a sediment pre-filter to catch particles and a carbon pre-filter to remove chlorine from municipal tap water. Chlorine destroys thin-film composite membranes, and even small amounts above 0.1 mg\/L cause permanent damage. Cleanflow stocks compatible \u003c\/span\u003e\u003ca href=\"https:\/\/cleanflow.net\/collections\/reverse-osmosis-filters\"\u003e\u003cspan\u003ereverse osmosis filters\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e for both stages. Replace pre-filters on schedule (typically every 6 to 12 months) to protect the membrane and keep it producing clean water for its full 2 to 3 year lifespan.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Franklin Water","offers":[{"title":"50 GPD Membrane \/ 1.8\" x 12\" (standard 1812 format)","offer_id":53995387191660,"sku":"FWME1812RO50","price":50.6,"currency_code":"CAD","in_stock":true},{"title":"75 GPD Membrane \/ 1.8\" x 12\" (standard 1812 format)","offer_id":53995387224428,"sku":"FWME1812RO75","price":59.0,"currency_code":"CAD","in_stock":true},{"title":"100 GPD Membrane \/ 1.8\" x 12\" (standard 1812 format)","offer_id":53995387257196,"sku":"FWME1812RO100","price":84.2,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/Franklin_FWME_1812_RO_Membrane.webp?v=1783093619","url":"https:\/\/cleanflow.net\/products\/fwme-1812","provider":"Cleanflow","version":"1.0","type":"link"}