{"product_id":"fwme4040ro-xlp","title":"Franklin FWME4040RO-XLP Extra Low Pressure RO Membrane","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eEnergy Efficient 4040 RO Membrane for Municipal Water, Bottled Water Production, and Second Pass RO at Extra Low Pressure\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIf your feed water is municipal, surface, or groundwater below 2,000 mg\/L TDS, a brackish water membrane wastes energy pushing against resistance you do not have. The \u003c\/span\u003e\u003cspan\u003eFranklin Water FWME4040RO-XLP extra-low-pressure RO membrane \u003c\/span\u003e\u003cspan\u003eoperates at just 100 psi, roughly half the pressure of a BW element, producing 9.8 m³\/d from 90 ft² of active area with 99.2% salt rejection. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eQuick Specs\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003eMembrane Type\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e Thin-Film Composite (TFC), Extra Low Pressure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003eElement Size\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e: \u003c\/strong\u003e4\" x 40\" (standard 4040 format)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003eActive Membrane Area\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e 90 ft² (8.4 m²)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003ePermeate Flow Rate:\u003c\/strong\u003e\u003cspan\u003e 9.8 m³\/d (GPD figure to be confirmed by Franklin Water)*\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003eStabilized Salt Rejection\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e 99.2%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003eStandard Test Pressure\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e: \u003c\/strong\u003e100 psi (0.69 MPa)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003eMaximum Feed TDS\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e 2,000 mg\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e NSF\/ANSI 61\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eKey Features and Benefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eOperates at 100 psi test pressure, roughly half what a brackish water membrane requires, making this a low-energy 4040 RO membrane that cuts pump sizing and electricity costs across every cubic metre of permeate produced.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003e99.2% stabilized salt rejection on feed water up to 2,000 mg\/L TDS, the right low-TDS RO membrane for clean municipal and groundwater sources that do not need brackish-grade pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003e90 ft² of active area, the largest in the Franklin Water 4040 lineup, produces 9.8 m³\/d at low energy cost, making it the most energy-efficient commercial 4040 membrane in the range.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eNSF\/ANSI 61 certified for drinking water contact, covering municipal water RO membrane applications from purified water production to bottled water RO lines.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eThis XLP 4040 RO membrane fits standard 4040 pressure vessels and drops into the same housings as the BW model and other industry-standard \u003c\/span\u003e\u003ca href=\"https:\/\/cleanflow.net\/collections\/reverse-osmosis-membranes\"\u003e\u003cspan\u003ereverse osmosis membranes\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, so switching from BW to XLP requires no housing changes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eCleaning pH range of 1 to 13 with 3.6 m³\/h (15.9 gpm) maximum feed flow for routine CIP cycles on low-fouling municipal and groundwater sources.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eFWME4040RO-XLP Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv align=\"left\" dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"240\"\u003e \u003ccol width=\"400\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFranklin Water Treatment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFWME4040RO-XLP\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMembrane Type\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThin-Film Composite (TFC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eElement Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eExtra Low Pressure (XLP)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eElement Size\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e4\" x 40\" (4040 standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e40\" \/ 1,016 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eDiameter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e3.9\" \/ 99 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePermeate Tube Inner Diameter\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e0.75\" \/ 19.1 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePermeate Tube Extension Length\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1.04\" \/ 26.5 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eActive Membrane Area\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e90 ft² \/ 8.4 m²\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003ePermeate Flow Rate\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e9.8 m³\/d [GPD to be confirmed]*\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eStabilized Salt Rejection\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e99.2%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMaximum Operating Pressure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e600 psi \/ 4.14 MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eStandard Test Pressure\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e100 psi \/ 0.69 MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTest Solution\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e500 mg\/L NaCl\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTest Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e25°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTest pH\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e7.5 to 8.0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTest Recovery\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e15%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMaximum Feed TDS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e2,000 mg\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMaximum Feed Flow Rate\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e3.6 m³\/h \/ 15.9 gpm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMaximum Feed SDI\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e5\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eFeed Chlorine Tolerance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u0026lt;0.1 mg\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003epH Range (Continuous)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e3 to 10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003epH Range (Short-Term Cleaning)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1 to 13\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eMax Element Pressure Drop\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e15 psi \/ 0.1 MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e0 to 45°C (32 to 113°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNSF\/ANSI 61\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eTypical Feed Water Sources\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMunicipal Water, Groundwater, Surface Water, Industrial Process Water\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eMunicipal tap water treatment for commercial and light industrial facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003ePurified water production and bottled water manufacturing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eSecond pass RO for high-purity permeate in pharmaceutical and electronics applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eSurface water and low-TDS groundwater treatment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eBoiler feed water and cooling tower makeup from clean sources\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eFood and beverage process water production\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003ePre-treatment for deionization and ultrapure water systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eIndustries\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eBottled water and beverage production\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eMunicipal water treatment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003ePharmaceutical and biotechnology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eElectronics and semiconductor manufacturing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eFood processing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli aria-level=\"1\" dir=\"ltr\"\u003e\n\u003cp role=\"presentation\" dir=\"ltr\"\u003e\u003cspan\u003eCommercial facility management\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eBuy the Franklin Water FWME4040RO-XLP Online from Cleanflow\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWhen your source water is clean and your priority is keeping operating costs low, the FWME4040RO-XLP is the extra low pressure 4040 reverse osmosis membrane to specify. At 9.8 m³\/d with 99.2% rejection at just 100 psi, it delivers output comparable to a BW element at a fraction of the energy cost. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCleanflow Utility Supply Company\u003c\/span\u003e\u003cspan\u003e is an authorized \u003c\/span\u003e\u003ca href=\"https:\/\/cleanflow.net\/collections\/franklin-water\"\u003e\u003cspan\u003eFranklin Water Treatment\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e distributor. The FWME4040RO-XLP, compatible \u003c\/span\u003e\u003ca href=\"https:\/\/cleanflow.net\/collections\/reverse-osmosis-system-accessories\"\u003e\u003cspan\u003ereverse osmosis system accessories\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, and replacement parts ship across Canada and the USA. Returns accepted within 30 days at \u003c\/span\u003e\u003ca href=\"https:\/\/returns.cleanflow.net\"\u003e\u003cspan\u003ereturns.cleanflow.net\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eShould I choose the XLP or BW version of the Franklin Water 4040 membrane?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eChoose the Franklin Water 4040 XLP membrane when your feed water TDS is below 2,000 mg\/L and energy costs matter. The XLP operates at 100 psi vs 225 psi for the BW, which means a smaller pump and lower electricity bills. Output is rated at 9.8 m³\/d. Choose the BW when your source water exceeds 2,000 mg\/L TDS or when you need the higher 99.6% rejection rate for brackish well water or industrial sources.\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eCan I use this membrane on well water?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOnly if your well water TDS stays below 2,000 mg\/L. As a low pressure commercial RO membrane in the 4 x 40 format, it is rated for clean groundwater, not brackish sources. Get a water analysis first. If TDS exceeds 2,000 mg\/L or the water has high hardness, iron, or manganese, spec the brackish water FWME4040RO-BW instead.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhat makes the FWME4040RO-XLP good for bottled water production?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBottled water operations treat clean municipal or spring water that typically tests below 500 mg\/L TDS. A brackish water membrane would work, but it wastes energy on water that is clean. This Franklin Water XLP membrane runs at 100 psi on that feed water, keeping electricity costs low across high-volume production lines. NSF\/ANSI 61 certification confirms it meets health effects requirements for drinking water contact.\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhat is a second-pass RO system, and why use this membrane for it?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eA second-pass RO system takes the permeate from a first-pass membrane and filters it again for higher purity. First-pass permeate typically has very low TDS, under 50 to 100 mg\/L, so the second-pass membrane needs minimal pressure to do its job. The FWME4040RO-XLP operates at just 100 psi with 9.8 m³\/d output, making it an efficient second-pass RO membrane in the 4040 format for pharmaceutical, electronics, and ultrapure water applications.\u003c\/span\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhat pre-treatment does the FWME4040RO-XLP need?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFeed water must have less than 0.1 mg\/L free chlorine and an SDI below 5. Install carbon pre-filtration for chlorine removal and sediment filtration for particulates. Cleanflow stocks compatible \u003c\/span\u003e\u003ca href=\"https:\/\/cleanflow.net\/collections\/reverse-osmosis-filters\"\u003e\u003cspan\u003ereverse osmosis filters\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e for both stages. Because this membrane runs on clean, low-TDS sources, fouling risk is lower than with brackish water, but pre-treatment is still required to protect this extra-low-pressure 4040 reverse osmosis membrane from chlorine damage.\u003c\/span\u003e\u003c\/p\u003e","brand":"Franklin Water","offers":[{"title":"4\" x 40\" (Standard 4040 Format) \/ 9.8 m³\/d","offer_id":54008897438060,"sku":"FWME4040RO-XLP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/Franklin_FWME4040RO-XLP_RO_Membrane.webp?v=1783088825","url":"https:\/\/cleanflow.net\/products\/fwme4040ro-xlp","provider":"Cleanflow","version":"1.0","type":"link"}