{"product_id":"fwme8040ro-bw","title":"Franklin FWME8040RO-BW Industrial Brackish Water RO Membrane","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eHigh-Capacity 8040 Brackish Water RO Membrane for Industrial Desalination\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWhen a 4040 element cannot keep up with your plant's demand, the FWME8040RO-BW is the industrial step up. The \u003c\/span\u003e\u003cspan\u003eFranklin Water FWME8040RO-BW industrial brackish water RO membrane \u003c\/span\u003e\u003cspan\u003eproduces 10,500 GPD from 400 ft² of active area with 99.7% stabilized salt rejection, the highest in the Franklin Water lineup. Tested at 225 psi with 2,000 mg\/L NaCl feed solution and rated for brackish source water up to 5,000 mg\/L TDS.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eQuick Specs\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eMembrane Type\u003c\/span\u003e\u003cspan\u003e: Thin-Film Composite (TFC), Brackish Water\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eElement Size\u003c\/span\u003e\u003cspan\u003e: 8\" x 40\" (standard 8040 format)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eActive Membrane Area\u003c\/span\u003e\u003cspan\u003e: 400 ft² (37.2 m²)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003ePermeate Flow Rate\u003c\/span\u003e\u003cspan\u003e: 10,500 GPD (39.7 m³\/d)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eStabilized Salt Rejection\u003c\/span\u003e\u003cspan\u003e: 99.7%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eStandard Test Pressure\u003c\/span\u003e\u003cspan\u003e: 225 psi (1.55 MPa)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eMaximum Feed TDS\u003c\/span\u003e\u003cspan\u003e: 5,000 mg\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eCertification\u003c\/span\u003e\u003cspan\u003e: NSF\/ANSI 61\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eKey Features and Benefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003e10,500 GPD from 400 ft² of active area, a high-capacity brackish water membrane that delivers more than four times the output of a 4040 element per housing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003e99.7% stabilized salt rejection on feed water up to 5,000 mg\/L TDS, the highest rejection rate of any industrial RO membrane in the 8040 format from \u003c\/span\u003e\u003ca href=\"https:\/\/cleanflow.net\/collections\/franklin-water\"\u003e\u003cspan\u003eFranklin Water\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003e170 m³\/h (74.8 gpm) maximum feed flow supports multi-element pressure vessels in large scale RO membrane systems for industrial water treatment and desalination.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eNSF\/ANSI 61 certified, meeting health-effects requirements for a water treatment plant RO membrane producing drinking water, process water, or boiler feed at industrial volumes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eThis 8 x 40 reverse osmosis membrane element fits standard 8-inch pressure vessels with a 1.12-inch permeate tube, compatible with Dow Filmtec BW30-400, Toray, and other \u003c\/span\u003e\u003ca href=\"https:\/\/cleanflow.net\/collections\/reverse-osmosis-membranes\"\u003e\u003cspan\u003ereverse osmosis membranes\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eCleaning pH range of 1 to 13 and 600 psi maximum operating pressure for the aggressive CIP protocols that industrial desalination plants running 8040 membranes require.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eFWME8040RO-BW Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv dir=\"ltr\" align=\"left\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"240\"\u003e\n\u003ccol width=\"400\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFranklin Water Treatment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFWME8040RO-BW\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMembrane Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThin-Film Composite (TFC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eElement Configuration\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBrackish Water (BW)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eElement Size\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e8\" x 40\" (8040 standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eLength\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e40\" \/ 1,016 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDiameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e7.9\" \/ 201 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePermeate Tube Inner Diameter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1.12\" \/ 28.5 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePermeate Tube Extension Length\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1.1\" \/ 28 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eActive Membrane Area\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e400 ft² \/ 37.2 m²\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePermeate Flow Rate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e10,500 GPD \/ 39.7 m³\/d\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eStabilized Salt Rejection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e99.7%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMaximum Operating Pressure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e600 psi \/ 4.14 MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eStandard Test Pressure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e225 psi \/ 1.55 MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTest Solution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e2,000 mg\/L NaCl\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTest Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e25°C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTest pH\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e7.5 to 8.0\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTest Recovery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e15%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMaximum Feed TDS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e5,000 mg\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMaximum Feed Flow Rate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e170 m³\/h \/ 74.8 gpm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMaximum Feed SDI\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e5\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFeed Chlorine Tolerance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e\u0026lt;0.1 mg\/L\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003epH Range (Continuous)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e3 to 10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003epH Range (Short-Term Cleaning)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1 to 13\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMax Element Pressure Drop\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e15 psi \/ 0.1 MPa\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e0 to 45°C (32 to 113°F)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCertification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNSF\/ANSI 61\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTypical Feed Water Sources\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBrackish Groundwater, Surface Water, Municipal Water, Industrial Process Water\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eMunicipal and industrial water treatment plants\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eBrackish groundwater desalination\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003ePower generation boiler feed water at plant scale\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003ePharmaceutical, biotechnology, and electronics process water\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eSteel, petrochemical, and chemical manufacturing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eLarge-scale cooling tower makeup water treatment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eWater reuse and reclamation systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003ePre-treatment for industrial-scale ultrapure water production\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eIndustries\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eMunicipal water utilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003ePower generation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003ePharmaceutical and biotechnology\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eElectronics and semiconductor manufacturing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003ePetrochemical and chemical processing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eSteel and metals manufacturing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eFood and beverage production at scale\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eBuy the Franklin Water FWME8040RO-BW RO Membrane Online from Cleanflow\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003eFWME8040RO-BW RO Membrane\u003c\/span\u003e\u003cspan\u003e puts industrial-scale brackish water treatment in a standard 8040 element. At 10,500 GPD with 99.7% rejection and NSF\/ANSI 61 certification, it is the high volume reverse osmosis membrane to specify when 4040 elements can no longer keep pace with plant demand. Cleanflow is an authorized Franklin Water Treatment distributor. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe FWME8040RO-BW industrial brackish water RO membrane, compatible \u003c\/span\u003e\u003ca href=\"https:\/\/cleanflow.net\/collections\/reverse-osmosis-system-accessories\"\u003e\u003cspan\u003ereverse osmosis system accessories\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e, and replacement parts ship across Canada and the USA. Returns accepted within 30 days at returns.cleanflow.net.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhen do I need an 8040 membrane instead of a 4040?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWhen your system design requires more than 2,500 GPD per element. A single Franklin Water 8040 BW membrane is a 10,500 GPD RO membrane with 400 ft² of active area, roughly four times the output of the 4040-BW. Fewer elements means fewer pressure vessels, less piping, and a smaller system footprint. Most plants switch to the BW 8040 RO membrane format once total system demand exceeds 50,000 to 100,000 GPD.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eHow many elements fit in an 8040 pressure vessel?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eStandard industrial pressure vessels hold 6 to 7 elements in series. With 10,500 GPD per element, a single 7-element vessel produces roughly 73,500 GPD. Plants scale by adding vessels in parallel arrays. The FWME8040RO-BW is sized for standard 8-inch vessels from Codeline, Protec, Wave Cyber, and other vessel manufacturers, making it a Franklin Water industrial reverse osmosis membrane that drops into most existing plant arrays.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eDoes 99.7% vs 99.6% rejection actually matter?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAt industrial volume, yes. On feed water at 3,000 mg\/L TDS, 99.6% rejection produces permeate at 12 mg\/L TDS. At 99.7%, permeate drops to 9 mg\/L. That 3 mg\/L difference compresses over hundreds of thousands of gallons per day and can determine whether your permeate meets spec without a second pass, saving an entire additional treatment stage.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eCan I use this for brackish groundwater desalination?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes, it handles brackish groundwater with TDS up to 5,000 mg\/L. As an 8040 brackish water reverse osmosis membrane, the FWME8040RO-BW industrial brackish water RO membrane is built for exactly this application. Get a full water analysis first. Brackish wells often carry iron, manganese, silica, and hydrogen sulfide that require specific pre-treatment (oxidation, media filtration, antiscalant dosing) before the RO stage to prevent fouling and scaling at these flow volumes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhat pre-treatment does an industrial-scale brackish water RO system need?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePlant-scale systems need more than a carbon cartridge and a sediment filter. Typical pre-treatment trains include multimedia filtration or ultrafiltration for SDI control, cartridge filtration at 5 microns as a final guard, antiscalant dosing for hardness and silica, and sodium bisulfite or carbon beds for dechlorination. \u003c\/span\u003e\u003cspan\u003eCleanflow Utility Supply Company\u003c\/span\u003e\u003cspan\u003e stocks compatible \u003c\/span\u003e\u003ca href=\"https:\/\/cleanflow.net\/collections\/reverse-osmosis-filters\"\u003e\u003cspan\u003ereverse osmosis filters\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e and cartridge housings for the filtration stages. Feed water must reach the membrane with SDI below 5, free chlorine below 0.1 mg\/L, and temperature between 0 and 45°C.\u003c\/span\u003e\u003c\/p\u003e","brand":"Franklin Water","offers":[{"title":"8\" x 40\" (Standard 8040 Format) \/ 10500 GPD (39.7 m³\/d)","offer_id":54008896618860,"sku":"FWME8040RO-BW","price":2175.59,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/Franklin_FWME8040RO-BW_RO_Membrane.webp?v=1783092930","url":"https:\/\/cleanflow.net\/products\/fwme8040ro-bw","provider":"Cleanflow","version":"1.0","type":"link"}