{"product_id":"hcp-fn-2-5u-submersible-pump","title":"HCP FN-2.5U Submersible Effluent Pump: 1\/2 HP, 120V, 2 inch Discharge, 70 GPM","description":"\u003ch2\u003eHCP FN-2.5U Effluent Pump for Low-Pressure Sewer and Light Sewage\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eIn septic systems, low-pressure sewer lines, and below-grade basins, the HCP FN-2.5U submersible effluent pump moves effluent and light sewage on 120V power. Its 0.5 HP motor delivers up to 70 GPM (about 4,200 GPH), and a non-clog vortex impeller passes solids up to 1-3\/8 inches (35 mm).\u003c\/p\u003e\n\u003ch3\u003eQuick Specs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorsepower\u003c\/strong\u003e: 0.5 HP (0.4 kW)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage \/ Phase:\u003c\/strong\u003e 120V 1-phase (also 208\/240V and 575V 3-phase), 6 A at 120V, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge:\u003c\/strong\u003e 2 inch (50 mm), Female NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Flow\u003c\/strong\u003e: 70 GPM (about 4,200 GPH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Head:\u003c\/strong\u003e 34 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolids Handling:\u003c\/strong\u003e 1-3\/8 inch (35 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpeller\u003c\/strong\u003e: Non-clog vortex\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCord\u003c\/strong\u003e: 30 ft, 3-prong 120V plug\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features of HCP FN-2.5U Submersible Effluent Pumps\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe non-clog vortex impeller passes solids up to 1-3\/8 inch (35 mm), so the FN-2.5U moves effluent and light sewage that would jam a clean-water pump.\u003c\/li\u003e\n\u003cli\u003eAn open inlet with no bottom strainer lets stringy solids pass straight into the volute instead of catching on a screen.\u003c\/li\u003e\n\u003cli\u003eA cast-iron (FC200) casing with a 304 stainless steel motor frame stands up to continuous wastewater duty.\u003c\/li\u003e\n\u003cli\u003eTwin mechanical seals, carbon\/ceramic over silicon carbide, run in an oil-filled chamber to keep sewage out of the motor. On the 120V model, a thermal protector and moisture sensor add a second layer of protection.\u003c\/li\u003e\n\u003cli\u003eThe IP68 sealed motor is rated for full submersion to 33 ft (10 m), for permanent basin and chamber installs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFN-2.5U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU (by voltage)\u003c\/td\u003e\n\u003ctd\u003eFN-2.5U-6117EPE3NX (120V), FN-2.5U-63AOEXE4NX (240V), FN-2.5U-635OEXE4NX (575V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSubmersible effluent \/ light-sewage pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Output\u003c\/td\u003e\n\u003ctd\u003e0.5 HP (0.4 kW); input 0.67 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Options\u003c\/td\u003e\n\u003ctd\u003e120V 1-phase, 208\/240V 3-phase, 575V 3-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e6 A (120V 1-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart Method\u003c\/td\u003e\n\u003ctd\u003eCapacitor (120V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed\u003c\/td\u003e\n\u003ctd\u003e3380 rpm (2 pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e2 inch (50 mm), Female NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Flow\u003c\/td\u003e\n\u003ctd\u003e70 GPM (about 4,200 GPH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Head\u003c\/td\u003e\n\u003ctd\u003e34 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolids Handling\u003c\/td\u003e\n\u003ctd\u003e1-3\/8 inch (35 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet\u003c\/td\u003e\n\u003ctd\u003eOpen (no strainer), passes solids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpeller\u003c\/td\u003e\n\u003ctd\u003eNon-clog vortex, PA+G50 (glass reinforced)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Seal\u003c\/td\u003e\n\u003ctd\u003eDouble (carbon\/ceramic upper, silicon carbide lower), oil-filled (VG32, 190 cc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCasing \/ Volute\u003c\/td\u003e\n\u003ctd\u003eCast iron (FC200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Frame\u003c\/td\u003e\n\u003ctd\u003e304 stainless steel (SUS304)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eSUS410 stainless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eExternal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Devices\u003c\/td\u003e\n\u003ctd\u003eThermal protector and moisture sensor (120V 1-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Submersion Depth\u003c\/td\u003e\n\u003ctd\u003e33 ft (10 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Liquid Temp\u003c\/td\u003e\n\u003ctd\u003e104F (40C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Starts per Hour\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord\u003c\/td\u003e\n\u003ctd\u003e30 ft, SJOW, 3-prong 120V plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e31 lb (14 kg), less cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003ecUL (UL778), CSA C22.2 No. 108-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHCP Pump Manufacturer Co., Ltd.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance Overview\u003c\/h3\u003e\n\u003cp\u003eThe FN-2.5U delivers up to 70 GPM and lifts to about 34 ft. It fits effluent transfer and low-pressure sewer runs that need steady flow through a 2-inch line more than high lift.\u003c\/p\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/HCP_FN-2.5U.png?v=1785044147\" alt=\"HCP FN-2.5U\"\u003e\n\u003ch3\u003eWhere the FN-2.5U fits by solids handling\u003c\/h3\u003e\n\u003cp\u003eSolids passage separates these pump types. The FN-2.5U sits between a filtered-effluent pump and a full sewage ejector.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePump type\u003c\/th\u003e\n\u003cth\u003eSolids passed\u003c\/th\u003e\n\u003cth\u003eTypical use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffluent pump\u003c\/td\u003e\n\u003ctd\u003eup to about 3\/4 inch\u003c\/td\u003e\n\u003ctd\u003eFiltered septic effluent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCP FN-2.5U\u003c\/td\u003e\n\u003ctd\u003eup to 1-3\/8 inch (35 mm)\u003c\/td\u003e\n\u003ctd\u003eEffluent and light sewage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSewage ejector\u003c\/td\u003e\n\u003ctd\u003eup to 2 inch\u003c\/td\u003e\n\u003ctd\u003eRaw residential sewage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEffluent transfer from septic and treatment tanks\u003c\/li\u003e\n\u003cli\u003eLow-pressure sewer (LPS) and pressurized dosing systems\u003c\/li\u003e\n\u003cli\u003eBelow-grade sewage basins in homes and small commercial buildings\u003c\/li\u003e\n\u003cli\u003eMound and aerobic on-site wastewater systems\u003c\/li\u003e\n\u003cli\u003eEffluent chambers and pump vaults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSet it in a basin with a check valve and control panel from the \u003ca href=\"https:\/\/cleanflow.net\/collections\/sewage-pump-accessories\"\u003esewage pump accessories\u003c\/a\u003e collection.\u003c\/p\u003e\n\u003ch3\u003eBuy the HCP FN-2.5U Submersible Effluent Pump Online from Cleanflow\u003c\/h3\u003e\n\u003cp\u003eFor effluent transfer, low-pressure sewer, and light sewage, the HCP FN-2.5U submersible effluent pump moves up to 70 GPM and passes 1-3\/8 inch solids on standard 120V power. \u003cstrong\u003e\u003ca href=\"https:\/\/cleanflow.net\/\"\u003eCleanflow Utility Supply Company\u003c\/a\u003e\u003c\/strong\u003e is an authorized HCP dealer, stocking and shipping \u003ca href=\"https:\/\/cleanflow.net\/collections\/hcp\"\u003eHCP pumps\u003c\/a\u003e across Canada and the continental USA, with free shipping on orders over $199.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrowse the full \u003ca href=\"https:\/\/cleanflow.net\/collections\/hcp-effluent-pumps\"\u003eeffluent pumps\u003c\/a\u003e range, then add the FN-2.5U to your cart or contact us to size the right pump for your system.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eDoes the HCP FN-2.5U replace the F-05U?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eYes. The FN-2.5U is HCP's replacement for the discontinued F-05U, with the same 0.5 HP, 2 inch effluent format and an updated FN-series motor. It comes in 120V, 240V, and 575V, so an F-05U swaps out without changing the discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eWhat size solids does the FN-2.5U pass?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eUp to 1-3\/8 inch (35 mm), through a non-clog vortex impeller. That covers effluent and light sewage. For raw sewage with solids up to 2 inches, step up to a full sewage ejector.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eEffluent pump or sewage pump, what is the difference?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eAn effluent pump like the FN-2.5U moves liquid with smaller solids (here, up to 1-3\/8 inch) from septic and low-pressure sewer systems. A sewage ejector handles raw sewage with solids up to 2 inches. Match the pump to the solids your system produces.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eHow much does the FN-2.5U move, and how high?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eUp to 70 GPM (about 4,200 GPH), with a maximum head near 34 ft. Flow is highest at low lift and falls as the head rises.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eIs the FN-2.5U certified, and does it have motor protection?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eYes. It carries CSA C22.2 No. 108-14 and cUL (UL778), with an IP68 sealed motor. The 120V model includes a built-in thermal protector and a moisture sensor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"HCP","offers":[{"title":"120 Volt - 1 Phase","offer_id":54081752596844,"sku":"FN-2.5U-6117EPE3NX","price":953.22,"currency_code":"CAD","in_stock":true},{"title":"208\/240 Volt - 3 Phase","offer_id":54081811644780,"sku":"FN-2.5U-63AOEXE4NX","price":1204.17,"currency_code":"CAD","in_stock":true},{"title":"575 Volt - 3 Phase","offer_id":54081811677548,"sku":"FN-2.5U-635OEXE4NX","price":1189.31,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/HCP_FN-2.5U_Submersible_Effluent_Pump.webp?v=1785044287","url":"https:\/\/cleanflow.net\/products\/hcp-fn-2-5u-submersible-pump","provider":"Cleanflow","version":"1.0","type":"link"}