{"product_id":"hcp-fn-2-5ul","title":"HCP FN-2.5UL 1\/2 HP Sewage Ejector Pump: 2-inch Discharge, 2-inch Solids, 6.4 Amps","description":"\u003ch2\u003eHCP FN-2.5UL 1\/2 HP Sewage Ejector Pump for 2-Inch Solids\u003c\/h2\u003e\n\u003cp\u003eA 1\/2 HP sewage ejector pump is the standard size for a single basement bathroom, and the HCP FN-2.5UL does that job on 6.4 amps. The \u003cstrong\u003eHCP FN-2.5UL\u003c\/strong\u003e sewage ejector pump passes the full 2-inch solids a residential ejector needs, lifting raw sewage from a below-grade basin up to the gravity main or septic tank. It is cUL and CSA certified, with 240V and 575V three-phase versions available.\u003c\/p\u003e\n\u003ch3\u003eQuick Specs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorsepower\u003c\/strong\u003e: 1\/2 HP (0.4 kW)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage \/ Phase\u003c\/strong\u003e: 120V 1-phase (6.4 A), also 240V 3-phase (2.4 A) and 575V 3-phase (1.0 A), 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge\u003c\/strong\u003e: 2 inch (50 mm), Female NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolids Handling\u003c\/strong\u003e: 2 inch (50 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Flow\u003c\/strong\u003e: 80 GPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Head\u003c\/strong\u003e: 22 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpeller\u003c\/strong\u003e: Non-clog vortex, glass-reinforced PA+G50 (casing: cast iron FC200)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection\u003c\/strong\u003e: Motor thermal protector and moisture sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications\u003c\/strong\u003e: cUL (UL778) and CSA C22.2 No. 108-14\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 15-1\/8 in tall, 9-5\/8 in wide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 32 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features of HCP FN-2.5UL 1\/2 HP Sewage Ejector Pumps\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe HCP FN-2.5UL sewage ejector pump passes solids up to 2 inches (50 mm) through its non-clog vortex impeller, the full residential rating, so a toilet can drain straight into the basin.\u003c\/li\u003e\n\u003cli\u003eIt draws 6.4 amps on 120V, well under the 9 amps or more that many 1\/2 HP ejectors pull. That leaves headroom on the older or shared circuits, which a basement retrofit usually lands on.\u003c\/li\u003e\n\u003cli\u003eA moisture sensor watches the seal chamber, and a motor thermal protector guards against overheating. Most 1\/2 HP ejectors carry thermal protection alone, with no early warning of a seal leak.\u003c\/li\u003e\n\u003cli\u003eTwin mechanical seals, carbon\/ceramic over silicon carbide, run in an oil bath to keep sewage out of the motor. The casing is cast iron (FC200), and the vortex impeller is glass-reinforced PA+G50.\u003c\/li\u003e\n\u003cli\u003eCertified to cUL (UL778) and CSA C22.2 No. 108-14, with an IP68-sealed motor. Three-phase versions (240V at 2.4 A, 575V at 1.0 A) suit light-commercial buildings, which few 1\/2 HP ejectors offer at all.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eCategory\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFN-2.5UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eF\/FN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSubmersible sewage ejector pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Output\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP (0.4 kW); input 0.67 kW (120V), 0.62 kW (3-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Options\u003c\/td\u003e\n\u003ctd\u003e120V 1-phase, 240V 3-phase, 575-600V 3-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e6.4 A (120V), 2.4 A (240V 3-ph), 1.0 A (575V 3-ph)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart Method\u003c\/td\u003e\n\u003ctd\u003eCapacitor (120V), DOL (3-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed\u003c\/td\u003e\n\u003ctd\u003e3380 rpm (2 pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Class\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e2 inch (50 mm), Female NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolids Handling\u003c\/td\u003e\n\u003ctd\u003e2 inch (50 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Flow\u003c\/td\u003e\n\u003ctd\u003e80 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Head\u003c\/td\u003e\n\u003ctd\u003e22 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Duty Point\u003c\/td\u003e\n\u003ctd\u003e58 GPM at 13.1 ft (30 percent efficiency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet\u003c\/td\u003e\n\u003ctd\u003eOpen (no strainer), passes solids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpeller\u003c\/td\u003e\n\u003ctd\u003eNon-clog vortex, PA+G50 (glass reinforced)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Seal\u003c\/td\u003e\n\u003ctd\u003eDouble (carbon\/ceramic upper, silicon carbide lower), oil-filled (VG32, 190 cc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCasing \/ Volute\u003c\/td\u003e\n\u003ctd\u003eCast iron (FC200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Frame\u003c\/td\u003e\n\u003ctd\u003e304 stainless steel (SUS304)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eSUS410 stainless\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eExternal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003e6201ZZ, 6202ZZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Devices\u003c\/td\u003e\n\u003ctd\u003eMotor thermal protector and moisture sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion-Proof\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Submersion Depth\u003c\/td\u003e\n\u003ctd\u003e33 ft (10 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Liquid Temp\u003c\/td\u003e\n\u003ctd\u003e104F (40C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Ambient Temp\u003c\/td\u003e\n\u003ctd\u003e32F to 104F (0C to 40C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Starts per Hour\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCord\u003c\/td\u003e\n\u003ctd\u003eSJOW (120V) \/ SOW (3-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eHeight 15-1\/8 in (384 mm); width 9-5\/8 in (244 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge Elbow Set\u003c\/td\u003e\n\u003ctd\u003eEF2-96 (DN50), optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e32 lb (14.5 kg) 1-phase; 31 lb (14 kg) 3-phase, less cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003ecUL (UL778), CSA C22.2 No. 108-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHCP Pump Manufacturer Co., Ltd.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance Overview\u003c\/h3\u003e\n\u003cp\u003eThe HCP FN-2.5UL sewage ejector pump moves up to 80 GPM and lifts to about 22 ft, with a standard duty point of 58 GPM at 13.1 ft. That suits the short lift from a basement basin up to a gravity main, which is what most residential ejector installs actually ask for. Size by the lift you need, not by peak flow.\u003c\/p\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/HCP_FN-2.5UL.png?v=1785132508\" alt=\"HCP FN-2.5UL\"\u003e\n\u003ch3\u003e1\/2 HP or 1 HP Sewage Ejector: Which Do You Need?\u003c\/h3\u003e\n\u003cp\u003eBoth pass 2-inch solids. Size by fixtures and lift, not by horsepower alone.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eFN-2.5UL (1\/2 HP)\u003c\/th\u003e\n\u003cth\u003eFN-21UL (1 HP)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest for\u003c\/td\u003e\n\u003ctd\u003eA single or half bath, a modest lift\u003c\/td\u003e\n\u003ctd\u003eA full bath with shower, more than one bath, or laundry tied in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax flow\u003c\/td\u003e\n\u003ctd\u003e80 GPM\u003c\/td\u003e\n\u003ctd\u003e100 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax head\u003c\/td\u003e\n\u003ctd\u003eAbout 22 ft\u003c\/td\u003e\n\u003ctd\u003eAbout 36 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent at 120V\u003c\/td\u003e\n\u003ctd\u003e6.4 A\u003c\/td\u003e\n\u003ctd\u003e10.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolids\u003c\/td\u003e\n\u003ctd\u003e2 inch\u003c\/td\u003e\n\u003ctd\u003e2 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRule of thumb:\u003c\/strong\u003e a 1\/2 HP sewage ejector pump like the FN-2.5UL handles a single basement bathroom with a short run to the main. Step up to the 1 HP FN-21UL for a full bathroom with a shower, more than one bathroom, laundry tied into the basin, or a long or high lift.\u003c\/p\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBasement and below-grade bathrooms\u003c\/li\u003e\n\u003cli\u003eRaw sewage transfer to a gravity main or septic tank\u003c\/li\u003e\n\u003cli\u003eSewage basins in homes and small commercial buildings\u003c\/li\u003e\n\u003cli\u003eSimplex sewage ejector packages\u003c\/li\u003e\n\u003cli\u003eLight-commercial buildings running 240V or 575V three-phase\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HCP FN-2.5UL sewage ejector pump stands 15-1\/8 inches (384 mm) tall and 9-5\/8 inches (244 mm) wide, so it drops into a standard sewage basin. Check the height against your basin, then build the install out with a float switch, check valve, and control panel from the \u003ca href=\"https:\/\/cleanflow.net\/collections\/sewage-pump-accessories\"\u003esewage pump accessories\u003c\/a\u003e collection.\u003c\/p\u003e\n\u003ch3\u003eBuy the HCP FN-2.5UL 1\/2 HP Sewage Ejector Pump Online from Cleanflow\u003c\/h3\u003e\n\u003cp\u003eFor a basement bathroom or a below-grade basin, the HCP FN-2.5UL sewage ejector pump passes full 2 inch solids on a 6.4 amp draw, with a moisture sensor, a double mechanical seal, and cUL and CSA certification behind it. \u003cstrong\u003eCleanflow Utility Supply Company\u003c\/strong\u003e is an authorized HCP dealer, stocking and shipping \u003ca href=\"https:\/\/cleanflow.net\/collections\/hcp\"\u003eHCP pumps\u003c\/a\u003e across Canada and the continental USA, with free shipping on orders over $199.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBrowse the full \u003ca href=\"https:\/\/cleanflow.net\/collections\/hcp-sewage-pumps\"\u003esewage pumps\u003c\/a\u003e range, then add the FN-2.5UL to your cart or contact us to size the right pump for your basin.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eWhat size sewage ejector pump do I need for a basement bathroom?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eFor a single basement bathroom with standard fixtures and a modest lift to the main, a 1\/2 HP sewage ejector pump is the standard size. The HCP FN-2.5UL sewage ejector pump is built for exactly that: 2 inch solids, a 2 inch discharge, about 22 ft of lift, and a 6.4 amp draw on 120V. Go up to 1 HP for a full bath with a shower, more than one bathroom, or a high lift. If only a sink or laundry drains into the basin and no toilet does, an effluent pump such as the FN-2.5U (1-3\/8 inch solids) is enough.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eFN-2.5UL or FN-21UL, which do I need?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eBoth are sewage ejectors that pass 2 inch solids, so choose by fixtures and lift. The 1\/2 HP FN-2.5UL covers a single bath with a short run, lifting to about 22 ft. The 1 HP FN-21UL lifts to about 36 ft and moves 100 GPM, for a full bathroom, several fixtures, or a deeper basin and a longer line.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eHow many amps does the FN-2.5UL draw?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eThe HCP FN-2.5UL sewage ejector pump draws 6.4 amps on 120V single-phase. Many 1\/2 HP sewage ejectors pull 9 amps or more, so it leaves more headroom on an older or shared basement circuit. The three-phase versions draw 2.4 A at 240V and 1.0 A at 575V.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eIs the FN-2.5UL certified for use in Canada?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eYes. It carries CSA C22.2 No. 108-14 as well as cUL (UL778), with an IP68 sealed motor. This matters more than it sounds. Electrical products sold and installed in Canada have to be certified by an accredited body or field-evaluated first. Many big-box sewage ejectors are UL-listed only, which can mean paying for a field evaluation before an inspector signs off on the install. The FN-2.5UL arrives already certified for Canada.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eWill the FN-2.5UL fit my sewage basin?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eThe pump stands 15-1\/8 inches (384 mm) tall and 9-5\/8 inches (244 mm) wide, which suits a standard residential sewage basin. Measure your basin depth and diameter, and leave room for the float to swing, before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eDoes the FN-2.5UL come in a three-phase version?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eYes, in 240V (2.4 A) and 575-600V (1.0 A) three-phase, alongside the 120V single-phase model. Three-phase is uncommon on a 1\/2 HP ejector and suits light-commercial and institutional buildings where 575V service is standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"HCP","offers":[{"title":"120 Volt - 1 Phase","offer_id":54081828454764,"sku":"FN-2.5UL-6117EPE3NX","price":995.4,"currency_code":"CAD","in_stock":true},{"title":"208\/240 Volt - 3 Phase","offer_id":54081828487532,"sku":"FN-2.5UL-63AOEXE4NX","price":1206.27,"currency_code":"CAD","in_stock":true},{"title":"575 Volt - 3 Phase","offer_id":54081828520300,"sku":"FN-2.5UL-635OEXE4NX","price":1174.6,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/HCPFN-2.5ULSubmersibleSewagePump_a752c2c4-4df7-4624-ad42-3eb29665aaaf.jpg?v=1783627283","url":"https:\/\/cleanflow.net\/products\/hcp-fn-2-5ul","provider":"Cleanflow","version":"1.0","type":"link"}