{"product_id":"lovibond-467481-spadns-reagent-solution-250-ml-bottle-fluoride-water-testing-reagent-for-spectrophotometers-colorimeters","title":"Lovibond 467481 SPADNS Reagent Solution, 250 mL Bottle | Fluoride Water Testing Reagent for Spectrophotometers \u0026 Colorimeters","description":"\u003ch2\u003e\u003cspan\u003eLovibond 467481 SPADNS Reagent Solution – 250 mL Fluoride Testing Reagent\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Lovibond 467481 SPADNS Reagent Solution is a high-quality laboratory reagent designed for the accurate determination of fluoride concentrations in drinking water, municipal water systems, and industrial water treatment applications. Supplied in a convenient 250 mL bottle, this reagent is commonly used with compatible spectrophotometers and colorimeters utilizing the SPADNS colorimetric method for fluoride analysis.\u003c\/p\u003e\n\u003cp\u003eWidely trusted by water treatment professionals, environmental laboratories, municipalities, and regulatory agencies, the SPADNS method provides reliable fluoride measurement results across a typical testing range of 0.2 to 2.0 mg\/L (ppm). Accurate fluoride monitoring helps ensure compliance with drinking water regulations while maintaining optimal water quality.\u003c\/p\u003e\n\u003cp\u003eManufactured by Lovibond, a recognized leader in water analysis equipment and reagents, the 467481 SPADNS Reagent Solution delivers dependable performance for routine water testing programs.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Lovibond 467481 SPADNS Reagent Solution is commonly used for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\u003cspan\u003eDrinking water fluoride testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMunicipal water treatment plants\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnvironmental water analysis\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGroundwater and well water monitoring\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLaboratory water quality testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eIndustrial process water analysis\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRegulatory compliance testing\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEducational and research laboratories\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eAccurate Fluoride Monitoring\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFluoride concentration testing is essential for maintaining safe drinking water quality and verifying compliance with local, provincial, state, and federal water treatment standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLovibond\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e467481\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSPADNS Reagent Solution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContainer Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 mL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest Parameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluoride\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTesting Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSPADNS Colorimetric Method\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeasurement Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 – 2.0 mg\/L (ppm) Fluoride\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWater Quality Analysis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompatible Instruments\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpectrophotometers and Colorimeters\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSample Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDrinking Water, Process Water, Environmental Water\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePackaging\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBottle\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntended Use\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLaboratory and Field Water Testing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003eFeatures \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eDesigned for Fluoride Analysis\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSpecifically formulated for accurate fluoride concentration measurements in water samples using the proven SPADNS testing method.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCompatible with Water Testing Instruments\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for use with compatible spectrophotometers and colorimeters commonly used in municipal and laboratory water testing programs.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eReliable and Repeatable Results\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eProvides dependable fluoride analysis to support water quality monitoring and regulatory compliance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eConvenient 250 mL Bottle\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eSupplied in an easy-to-handle bottle size suitable for routine testing applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eTrusted Lovibond Quality\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eManufactured by Lovibond, a globally recognized provider of water testing equipment, reagents, and analytical solutions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eWhat is the Lovibond 467481 SPADNS Reagent Solution used for?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eIt is used to measure fluoride concentrations in water samples using the SPADNS colorimetric testing method.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat testing range does this reagent support?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe reagent is commonly used to measure fluoride concentrations from approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.2 to 2.0 mg\/L (ppm)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat size bottle is supplied?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThis product is supplied in a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e250 mL bottle\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat instruments can be used with this reagent?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe SPADNS Reagent Solution is typically used with compatible spectrophotometers and colorimeters designed for fluoride analysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIs this reagent suitable for drinking water testing?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. It is commonly used for drinking water analysis, municipal water treatment monitoring, and regulatory compliance testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWhat does the SPADNS method measure?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe SPADNS method is a colorimetric testing procedure used to determine fluoride concentrations in water samples.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eWho commonly uses this reagent?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eMunicipal water treatment facilities, environmental laboratories, industrial water treatment operators, researchers, and water quality professionals frequently use SPADNS reagents for fluoride monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eIs this an original Lovibond reagent?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eYes. Part number 467481 is a genuine Lovibond SPADNS Reagent Solution manufactured for water quality testing applications.\u003c\/span\u003e\u003c\/p\u003e","brand":"Lovibond","offers":[{"title":"250 mL Bottle","offer_id":53944952652140,"sku":"467481","price":51.24,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/467481_spadns_reagent_250_ml_mb2-removebg.png?v=1782250322","url":"https:\/\/cleanflow.net\/products\/lovibond-467481-spadns-reagent-solution-250-ml-bottle-fluoride-water-testing-reagent-for-spectrophotometers-colorimeters","provider":"Cleanflow","version":"1.0","type":"link"}