{"product_id":"milwaukee-mw150-max-bench-ph-orp-temperature-meter-lab-grade-3-in-1-meter-with-atc-glp-0-01-ph-accuracy","title":"Milwaukee MW150 MAX Bench pH\/ORP\/Temperature Meter | Lab Grade 3-in-1 Meter with ATC, GLP \u0026 ±0.01 pH Accuracy","description":"\u003ch2 data-section-id=\"dq32hb\" data-start=\"157\" data-end=\"210\" class=\"PDq2pG_selectionAnchorContainer\"\u003eMilwaukee MW150 MAX Bench pH\/ORP\/Temperature Meter\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"212\" data-end=\"671\"\u003eThe Milwaukee MW150 MAX Bench Meter is a professional laboratory instrument designed for highly accurate measurement of pH, oxidation-reduction potential (ORP), and temperature. Combining ±0.01 pH accuracy, automatic temperature compensation (ATC), up to three-point automatic calibration, and a refillable double-junction pH electrode, the MW150 MAX delivers dependable laboratory-grade performance for demanding testing applications.\u003c\/p\u003e\n\u003cp data-start=\"673\" data-end=\"1145\"\u003eDesigned with a compact footprint that conserves valuable bench space, the MW150 MAX is ideal for water treatment plants, environmental laboratories, breweries, wineries, hydroponics, agriculture, food processing, aquaculture, research laboratories, and industrial quality control. The rugged design, intuitive controls, and dedicated Good Laboratory Practice (GLP) functions make it a reliable choice for professionals who require consistent, repeatable measurements.\u003c\/p\u003e\n\u003cp data-start=\"1147\" data-end=\"1338\"\u003eSupplied with the Milwaukee MA917B\/1 refillable glass pH electrode and MA831R stainless steel temperature probe, the MW150 MAX is ready for precision pH analysis right out of the box.\u003c\/p\u003e\n\u003chr data-start=\"1340\" data-end=\"1343\"\u003e\n\u003ch2 data-section-id=\"1fvxudu\" data-start=\"1345\" data-end=\"1402\"\u003eMeasure pH, ORP \u0026amp; Temperature with Laboratory Accuracy\u003c\/h2\u003e\n\u003cp data-start=\"1404\" data-end=\"1501\"\u003eThe MW150 MAX combines three essential laboratory measurements into one professional bench meter.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hgxiwk\" data-start=\"1503\" data-end=\"1521\"\u003epH Measurement\u003c\/h3\u003e\n\u003cp data-start=\"1523\" data-end=\"1678\"\u003eMeasure pH from \u003cstrong data-start=\"1539\" data-end=\"1557\"\u003e-2.00 to 20.00\u003c\/strong\u003e with outstanding \u003cstrong data-start=\"1575\" data-end=\"1596\"\u003e±0.01 pH accuracy\u003c\/strong\u003e, making the meter suitable for analytical, industrial, and research applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"yiaedd\" data-start=\"1680\" data-end=\"1699\"\u003eORP Measurement\u003c\/h3\u003e\n\u003cp data-start=\"1701\" data-end=\"1863\"\u003eMeasure oxidation-reduction potential from \u003cstrong data-start=\"1744\" data-end=\"1756\"\u003e±2000 mV\u003c\/strong\u003e for monitoring oxidation, disinfection, and chemical treatment processes. (ORP electrode sold separately.)\u003c\/p\u003e\n\u003ch3 data-section-id=\"eoy0ps\" data-start=\"1865\" data-end=\"1892\"\u003eTemperature Measurement\u003c\/h3\u003e\n\u003cp data-start=\"1894\" data-end=\"2083\"\u003eMeasure temperatures from \u003cstrong data-start=\"1920\" data-end=\"1958\"\u003e-20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/strong\u003e using the included stainless steel temperature probe while automatically compensating pH measurements for improved accuracy.\u003c\/p\u003e\n\u003chr data-start=\"2085\" data-end=\"2088\"\u003e\n\u003ch2 data-section-id=\"3ipjz4\" data-start=\"2090\" data-end=\"2115\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2117\" data-end=\"3285\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2117\" data-end=\"2144\"\u003e\n\u003ctr data-start=\"2117\" data-end=\"2144\"\u003e\n\u003cth data-start=\"2117\" data-end=\"2133\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2133\" data-end=\"2144\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2172\" data-end=\"3285\"\u003e\n\u003ctr data-start=\"2172\" data-end=\"2212\"\u003e\n\u003ctd data-start=\"2172\" data-end=\"2187\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-start=\"2187\" data-end=\"2212\" data-col-size=\"md\"\u003eMilwaukee Instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2213\" data-end=\"2234\"\u003e\n\u003ctd data-start=\"2213\" data-end=\"2221\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"2221\" data-end=\"2234\" data-col-size=\"md\"\u003eMW150 MAX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2235\" data-end=\"2288\"\u003e\n\u003ctd data-start=\"2235\" data-end=\"2250\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2250\" data-end=\"2288\" data-col-size=\"md\"\u003eBench pH \/ ORP \/ Temperature Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2289\" data-end=\"2321\"\u003e\n\u003ctd data-start=\"2289\" data-end=\"2300\" data-col-size=\"sm\"\u003epH Range\u003c\/td\u003e\n\u003ctd data-start=\"2300\" data-end=\"2321\" data-col-size=\"md\"\u003e-2.00 to 20.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2322\" data-end=\"2348\"\u003e\n\u003ctd data-start=\"2322\" data-end=\"2334\" data-col-size=\"sm\"\u003eORP Range\u003c\/td\u003e\n\u003ctd data-start=\"2334\" data-end=\"2348\" data-col-size=\"md\"\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2349\" data-end=\"2407\"\u003e\n\u003ctd data-start=\"2349\" data-end=\"2369\" data-col-size=\"sm\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd data-start=\"2369\" data-end=\"2407\" data-col-size=\"md\"\u003e-20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2408\" data-end=\"2435\"\u003e\n\u003ctd data-start=\"2408\" data-end=\"2424\" data-col-size=\"sm\"\u003epH Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2424\" data-end=\"2435\" data-col-size=\"md\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2436\" data-end=\"2463\"\u003e\n\u003ctd data-start=\"2436\" data-end=\"2453\" data-col-size=\"sm\"\u003eORP Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2453\" data-end=\"2463\" data-col-size=\"md\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2464\" data-end=\"2506\"\u003e\n\u003ctd data-start=\"2464\" data-end=\"2489\" data-col-size=\"sm\"\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd data-start=\"2489\" data-end=\"2506\" data-col-size=\"md\"\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2507\" data-end=\"2533\"\u003e\n\u003ctd data-start=\"2507\" data-end=\"2521\" data-col-size=\"sm\"\u003epH Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2521\" data-end=\"2533\" data-col-size=\"md\"\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2534\" data-end=\"2558\"\u003e\n\u003ctd data-start=\"2534\" data-end=\"2549\" data-col-size=\"sm\"\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2549\" data-end=\"2558\" data-col-size=\"md\"\u003e±1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2559\" data-end=\"2601\"\u003e\n\u003ctd data-start=\"2559\" data-end=\"2582\" data-col-size=\"sm\"\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd data-start=\"2582\" data-end=\"2601\" data-col-size=\"md\"\u003e±0.4°C (±0.8°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2602\" data-end=\"2648\"\u003e\n\u003ctd data-start=\"2602\" data-end=\"2619\" data-col-size=\"sm\"\u003epH Calibration\u003c\/td\u003e\n\u003ctd data-start=\"2619\" data-end=\"2648\" data-col-size=\"md\"\u003eAutomatic, Up to 3 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2649\" data-end=\"2714\"\u003e\n\u003ctd data-start=\"2649\" data-end=\"2668\" data-col-size=\"sm\"\u003eStandard Buffers\u003c\/td\u003e\n\u003ctd data-start=\"2668\" data-end=\"2714\" data-col-size=\"md\"\u003e1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2715\" data-end=\"2765\"\u003e\n\u003ctd data-start=\"2715\" data-end=\"2742\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"2742\" data-end=\"2765\" data-col-size=\"md\"\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2766\" data-end=\"2845\"\u003e\n\u003ctd data-start=\"2766\" data-end=\"2790\" data-col-size=\"sm\"\u003eIncluded pH Electrode\u003c\/td\u003e\n\u003ctd data-start=\"2790\" data-end=\"2845\" data-col-size=\"md\"\u003eMA917B\/1 Refillable Double Junction Glass Electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2846\" data-end=\"2907\"\u003e\n\u003ctd data-start=\"2846\" data-end=\"2875\" data-col-size=\"sm\"\u003eIncluded Temperature Probe\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2875\" data-end=\"2907\"\u003eMA831R Stainless Steel Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2908\" data-end=\"2954\"\u003e\n\u003ctd data-start=\"2908\" data-end=\"2924\" data-col-size=\"sm\"\u003eORP Electrode\u003c\/td\u003e\n\u003ctd data-start=\"2924\" data-end=\"2954\" data-col-size=\"md\"\u003eOptional (Sold Separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2955\" data-end=\"3002\"\u003e\n\u003ctd data-start=\"2955\" data-end=\"2965\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2965\" data-end=\"3002\" data-col-size=\"md\"\u003eLarge Dual-Level Alphanumeric LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3003\" data-end=\"3047\"\u003e\n\u003ctd data-start=\"3003\" data-end=\"3018\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3018\" data-end=\"3047\" data-col-size=\"md\"\u003e12 VDC Adapter (Included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3048\" data-end=\"3083\"\u003e\n\u003ctd data-start=\"3048\" data-end=\"3058\" data-col-size=\"sm\"\u003eBattery\u003c\/td\u003e\n\u003ctd data-start=\"3058\" data-end=\"3083\" data-col-size=\"md\"\u003eBuilt-in Rechargeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3084\" data-end=\"3127\"\u003e\n\u003ctd data-start=\"3084\" data-end=\"3102\" data-col-size=\"sm\"\u003eBattery Runtime\u003c\/td\u003e\n\u003ctd data-start=\"3102\" data-end=\"3127\" data-col-size=\"md\"\u003eApproximately 8 Hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3128\" data-end=\"3189\"\u003e\n\u003ctd data-start=\"3128\" data-end=\"3144\" data-col-size=\"sm\"\u003eAuto Shut-Off\u003c\/td\u003e\n\u003ctd data-start=\"3144\" data-end=\"3189\" data-col-size=\"md\"\u003eSelectable (5, 10, 30, 60 Minutes or Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3190\" data-end=\"3224\"\u003e\n\u003ctd data-start=\"3190\" data-end=\"3203\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"3203\" data-end=\"3224\" data-col-size=\"md\"\u003e230 × 160 × 95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3225\" data-end=\"3254\"\u003e\n\u003ctd data-start=\"3225\" data-end=\"3234\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"3234\" data-end=\"3254\"\u003e0.9 kg (2.0 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3255\" data-end=\"3285\"\u003e\n\u003ctd data-start=\"3255\" data-end=\"3266\" data-col-size=\"sm\"\u003eWarranty\u003c\/td\u003e\n\u003ctd data-start=\"3266\" data-end=\"3285\" data-col-size=\"md\"\u003e3 Years (Meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3287\" data-end=\"3290\"\u003e\n\u003ch2 data-section-id=\"gh0k9s\" data-start=\"3292\" data-end=\"3314\"\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1reg8ww\" data-start=\"3316\" data-end=\"3345\"\u003eLaboratory-Grade Accuracy\u003c\/h3\u003e\n\u003cp data-start=\"3347\" data-end=\"3476\"\u003eDelivers \u003cstrong data-start=\"3356\" data-end=\"3377\"\u003e±0.01 pH accuracy\u003c\/strong\u003e, making it suitable for professional laboratory testing, research, and industrial quality control.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1okh8dj\" data-start=\"3478\" data-end=\"3518\"\u003eThree Measurements in One Instrument\u003c\/h3\u003e\n\u003cp data-start=\"3520\" data-end=\"3592\"\u003eMeasure \u003cstrong data-start=\"3528\" data-end=\"3556\"\u003epH, ORP, and temperature\u003c\/strong\u003e using one compact laboratory meter.\u003c\/p\u003e\n\u003ch3 data-section-id=\"61osx\" data-start=\"3594\" data-end=\"3618\"\u003eCompact Bench Design\u003c\/h3\u003e\n\u003cp data-start=\"3620\" data-end=\"3717\"\u003eThe small footprint saves valuable workspace while providing professional laboratory performance.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1v9gfer\" data-start=\"3719\" data-end=\"3757\"\u003eAutomatic Temperature Compensation\u003c\/h3\u003e\n\u003cp data-start=\"3759\" data-end=\"3901\"\u003eThe included \u003cstrong data-start=\"3772\" data-end=\"3800\"\u003eMA831R temperature probe\u003c\/strong\u003e automatically compensates pH measurements for improved accuracy across changing sample temperatures.\u003c\/p\u003e\n\u003ch3 data-section-id=\"b35s3i\" data-start=\"3903\" data-end=\"3940\"\u003eThree-Point Automatic Calibration\u003c\/h3\u003e\n\u003cp data-start=\"3942\" data-end=\"4066\"\u003eSupports \u003cstrong data-start=\"3951\" data-end=\"3994\"\u003eup to three-point automatic calibration\u003c\/strong\u003e using seven standard buffer solutions for highly accurate measurements.\u003c\/p\u003e\n\u003ch3 data-section-id=\"19bxhri\" data-start=\"4068\" data-end=\"4121\"\u003eProfessional Refillable Double-Junction Electrode\u003c\/h3\u003e\n\u003cp data-start=\"4123\" data-end=\"4174\"\u003eThe supplied \u003cstrong data-start=\"4136\" data-end=\"4164\"\u003eMA917B\/1 glass electrode\u003c\/strong\u003e features:\u003c\/p\u003e\n\u003cul data-start=\"4176\" data-end=\"4376\"\u003e\n\u003cli data-section-id=\"gcn7jb\" data-start=\"4176\" data-end=\"4228\"\u003eDouble-junction construction for difficult samples\u003c\/li\u003e\n\u003cli data-section-id=\"6krp94\" data-start=\"4229\" data-end=\"4253\"\u003eRefillable electrolyte\u003c\/li\u003e\n\u003cli data-section-id=\"1pb0m81\" data-start=\"4254\" data-end=\"4271\"\u003eLow maintenance\u003c\/li\u003e\n\u003cli data-section-id=\"77waum\" data-start=\"4272\" data-end=\"4310\"\u003eImproved resistance to contamination\u003c\/li\u003e\n\u003cli data-section-id=\"1wdzf4p\" data-start=\"4311\" data-end=\"4330\"\u003eLong service life\u003c\/li\u003e\n\u003cli data-section-id=\"19vlc50\" data-start=\"4331\" data-end=\"4376\"\u003eStandard BNC connector for easy replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"xzwevb\" data-start=\"4378\" data-end=\"4412\"\u003eGood Laboratory Practice (GLP)\u003c\/h3\u003e\n\u003cp data-start=\"4414\" data-end=\"4539\"\u003eDedicated GLP functions record calibration information and instrument status for improved quality assurance and traceability.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xgdeb9\" data-start=\"4541\" data-end=\"4575\"\u003eLarge Alphanumeric LCD Display\u003c\/h3\u003e\n\u003cp data-start=\"4577\" data-end=\"4686\"\u003eThe dual-level display presents measurements and operating information clearly for efficient laboratory work.\u003c\/p\u003e\n\u003ch3 data-section-id=\"d08jjg\" data-start=\"4688\" data-end=\"4712\"\u003eRechargeable Battery\u003c\/h3\u003e\n\u003cp data-start=\"4714\" data-end=\"4837\"\u003eOperate for approximately \u003cstrong data-start=\"4740\" data-end=\"4751\"\u003e8 hours\u003c\/strong\u003e on the built-in rechargeable battery or continuously using the included power supply.\u003c\/p\u003e\n\u003chr data-start=\"4839\" data-end=\"4842\"\u003e\n\u003ch2 data-section-id=\"19vd27d\" data-start=\"4844\" data-end=\"4865\"\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp data-start=\"4867\" data-end=\"4904\"\u003eThe Milwaukee MW150 MAX is ideal for:\u003c\/p\u003e\n\u003cul data-start=\"4906\" data-end=\"5188\"\u003e\n\u003cli data-section-id=\"166mw0y\" data-start=\"4906\" data-end=\"4935\"\u003eDrinking water laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"a50kdp\" data-start=\"4936\" data-end=\"4958\"\u003eWastewater treatment\u003c\/li\u003e\n\u003cli data-section-id=\"1iu5xdh\" data-start=\"4959\" data-end=\"4987\"\u003eEnvironmental laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"4988\" data-end=\"5011\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"10gwr6y\" data-start=\"5012\" data-end=\"5026\"\u003eUniversities\u003c\/li\u003e\n\u003cli data-section-id=\"12asmdm\" data-start=\"5027\" data-end=\"5036\"\u003eBrewing\u003c\/li\u003e\n\u003cli data-section-id=\"12919dm\" data-start=\"5037\" data-end=\"5049\"\u003eWinemaking\u003c\/li\u003e\n\u003cli data-section-id=\"6dow6g\" data-start=\"5050\" data-end=\"5063\"\u003eHydroponics\u003c\/li\u003e\n\u003cli data-section-id=\"13ecb4p\" data-start=\"5064\" data-end=\"5077\"\u003eAgriculture\u003c\/li\u003e\n\u003cli data-section-id=\"p02ge8\" data-start=\"5078\" data-end=\"5091\"\u003eAquaculture\u003c\/li\u003e\n\u003cli data-section-id=\"1pzpf6p\" data-start=\"5092\" data-end=\"5109\"\u003eFood processing\u003c\/li\u003e\n\u003cli data-section-id=\"60wbl6\" data-start=\"5110\" data-end=\"5139\"\u003ePharmaceutical laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"52ibyd\" data-start=\"5140\" data-end=\"5168\"\u003eIndustrial quality control\u003c\/li\u003e\n\u003cli data-section-id=\"1q12ni6\" data-start=\"5169\" data-end=\"5188\"\u003eChemical analysis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5190\" data-end=\"5193\"\u003e\n\u003ch2 data-section-id=\"3gv3a9\" data-start=\"5195\" data-end=\"5222\"\u003eProbe Care \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp data-start=\"5224\" data-end=\"5306\"\u003eProper electrode maintenance ensures accurate measurements and extends probe life.\u003c\/p\u003e\n\u003ch3 data-section-id=\"w9x5of\" data-start=\"5308\" data-end=\"5319\"\u003eStorage\u003c\/h3\u003e\n\u003cp data-start=\"5321\" data-end=\"5500\"\u003eStore the pH electrode in \u003cstrong data-start=\"5347\" data-end=\"5384\"\u003eMilwaukee MA9015 Storage Solution\u003c\/strong\u003e. Never store the probe in distilled or reverse osmosis water, as this can permanently reduce electrode sensitivity.\u003c\/p\u003e\n\u003ch3 data-section-id=\"mfh9yb\" data-start=\"5502\" data-end=\"5514\"\u003eCleaning\u003c\/h3\u003e\n\u003cp data-start=\"5516\" data-end=\"5671\"\u003eRegularly soak the electrode in \u003cstrong data-start=\"5548\" data-end=\"5586\"\u003eMilwaukee MA9016 Cleaning Solution\u003c\/strong\u003e for approximately 20 minutes to remove sample residue and prevent junction clogging.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1v43k86\" data-start=\"5673\" data-end=\"5695\"\u003eRoutine Inspection\u003c\/h3\u003e\n\u003cp data-start=\"5697\" data-end=\"5723\"\u003eInspect the electrode for:\u003c\/p\u003e\n\u003cul data-start=\"5725\" data-end=\"5822\"\u003e\n\u003cli data-section-id=\"ntcbmx\" data-start=\"5725\" data-end=\"5739\"\u003eGlass damage\u003c\/li\u003e\n\u003cli data-section-id=\"1mjy5fk\" data-start=\"5740\" data-end=\"5752\"\u003eCable wear\u003c\/li\u003e\n\u003cli data-section-id=\"116tnwe\" data-start=\"5753\" data-end=\"5776\"\u003eClean, dry connectors\u003c\/li\u003e\n\u003cli data-section-id=\"1c27u8v\" data-start=\"5777\" data-end=\"5822\"\u003eSalt deposits (rinse away with clean water)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wzkpnw\" data-start=\"5824\" data-end=\"5839\"\u003eCalibration\u003c\/h3\u003e\n\u003cp data-start=\"5841\" data-end=\"5873\"\u003eFor maximum accuracy, calibrate:\u003c\/p\u003e\n\u003cul data-start=\"5875\" data-end=\"5996\"\u003e\n\u003cli data-section-id=\"1o9zdoj\" data-start=\"5875\" data-end=\"5905\"\u003eBefore critical measurements\u003c\/li\u003e\n\u003cli data-section-id=\"1lk6end\" data-start=\"5906\" data-end=\"5922\"\u003eAfter cleaning\u003c\/li\u003e\n\u003cli data-section-id=\"1yxdfd5\" data-start=\"5923\" data-end=\"5952\"\u003eFollowing long-term storage\u003c\/li\u003e\n\u003cli data-section-id=\"1pk89sq\" data-start=\"5953\" data-end=\"5996\"\u003eWhenever measurement accuracy is in doubt\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5998\" data-end=\"6019\"\u003eMilwaukee recommends:\u003c\/p\u003e\n\u003cul data-start=\"6021\" data-end=\"6176\"\u003e\n\u003cli data-section-id=\"12hqdyi\" data-start=\"6021\" data-end=\"6044\"\u003eMA9004 pH 4.01 Buffer\u003c\/li\u003e\n\u003cli data-section-id=\"1d1iiru\" data-start=\"6045\" data-end=\"6068\"\u003eMA9007 pH 7.01 Buffer\u003c\/li\u003e\n\u003cli data-section-id=\"ozf5ol\" data-start=\"6069\" data-end=\"6123\"\u003eMA9010 pH 10.01 Buffer (for three-point calibration)\u003c\/li\u003e\n\u003cli data-section-id=\"pui5l5\" data-start=\"6124\" data-end=\"6149\"\u003eMA9015 Storage Solution\u003c\/li\u003e\n\u003cli data-section-id=\"14qf3na\" data-start=\"6150\" data-end=\"6176\"\u003eMA9016 Cleaning Solution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6178\" data-end=\"6299\"\u003eThe Milwaukee \u003cstrong data-start=\"6192\" data-end=\"6208\"\u003epH-START Kit\u003c\/strong\u003e conveniently includes the most commonly used calibration, cleaning, and storage solutions.\u003c\/p\u003e\n\u003chr data-start=\"6301\" data-end=\"6304\"\u003e\n\u003ch2 data-section-id=\"1r8frcv\" data-start=\"6306\" data-end=\"6335\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 data-section-id=\"2sq9w5\" data-start=\"6337\" data-end=\"6373\"\u003eWhat does the MW150 MAX measure?\u003c\/h3\u003e\n\u003cp data-start=\"6375\" data-end=\"6459\"\u003eThe MW150 MAX measures \u003cstrong data-start=\"6398\" data-end=\"6458\"\u003epH, oxidation-reduction potential (ORP), and temperature\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"khx9iv\" data-start=\"6461\" data-end=\"6491\"\u003eHow accurate is the meter?\u003c\/h3\u003e\n\u003cp data-start=\"6493\" data-end=\"6581\"\u003eThe MW150 MAX provides \u003cstrong data-start=\"6516\" data-end=\"6528\"\u003e±0.01 pH\u003c\/strong\u003e, \u003cstrong data-start=\"6530\" data-end=\"6543\"\u003e±1 mV ORP\u003c\/strong\u003e, and \u003cstrong data-start=\"6549\" data-end=\"6580\"\u003e±0.4°C temperature accuracy\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1hdrzut\" data-start=\"6583\" data-end=\"6614\"\u003eIs a pH electrode included?\u003c\/h3\u003e\n\u003cp data-start=\"6616\" data-end=\"6713\"\u003eYes. The meter includes the \u003cstrong data-start=\"6644\" data-end=\"6712\"\u003eMilwaukee MA917B\/1 refillable double-junction glass pH electrode\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"cu6spq\" data-start=\"6715\" data-end=\"6748\"\u003eIs an ORP electrode included?\u003c\/h3\u003e\n\u003cp data-start=\"6750\" data-end=\"6795\"\u003eNo. The ORP electrode is \u003cstrong data-start=\"6775\" data-end=\"6794\"\u003esold separately\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1onfq65\" data-start=\"6797\" data-end=\"6857\"\u003eDoes the meter automatically compensate for temperature?\u003c\/h3\u003e\n\u003cp data-start=\"6859\" data-end=\"6999\"\u003eYes. The included \u003cstrong data-start=\"6877\" data-end=\"6905\"\u003eMA831R temperature probe\u003c\/strong\u003e provides \u003cstrong data-start=\"6915\" data-end=\"6959\"\u003eAutomatic Temperature Compensation (ATC)\u003c\/strong\u003e. Manual compensation is also available.\u003c\/p\u003e\n\u003ch3 data-section-id=\"5z7dpb\" data-start=\"7001\" data-end=\"7047\"\u003eHow many calibration points are supported?\u003c\/h3\u003e\n\u003cp data-start=\"7049\" data-end=\"7157\"\u003eThe MW150 MAX supports \u003cstrong data-start=\"7072\" data-end=\"7115\"\u003eup to three-point automatic calibration\u003c\/strong\u003e using seven standard pH buffer solutions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"mutgf8\" data-start=\"7159\" data-end=\"7193\"\u003eCan the electrode be replaced?\u003c\/h3\u003e\n\u003cp data-start=\"7195\" data-end=\"7314\"\u003eYes. The MA917B\/1 uses a standard \u003cstrong data-start=\"7229\" data-end=\"7246\"\u003eBNC connector\u003c\/strong\u003e, allowing easy replacement with compatible Milwaukee pH electrodes.\u003c\/p\u003e\n\u003ch3 data-section-id=\"28ugt2\" data-start=\"7316\" data-end=\"7351\"\u003eWho is this meter designed for?\u003c\/h3\u003e\n\u003cp data-start=\"7353\" data-end=\"7574\"\u003eThe MW150 MAX is ideal for laboratories, breweries, wineries, hydroponic growers, water treatment facilities, food processors, environmental monitoring professionals, researchers, and industrial quality control personnel.\u003c\/p\u003e","brand":"Milwaukee Instruments","offers":[{"title":"Default Title","offer_id":53989760696684,"sku":"MW150US","price":1031.52,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/MW150_Top__19773.1605818587_1.jpg?v=1783101393","url":"https:\/\/cleanflow.net\/products\/milwaukee-mw150-max-bench-ph-orp-temperature-meter-lab-grade-3-in-1-meter-with-atc-glp-0-01-ph-accuracy","provider":"Cleanflow","version":"1.0","type":"link"}