{"product_id":"milwaukee-mw401-pro-low-range-portable-total-dissolved-solids-tds-meter","title":"Milwaukee MW401 PRO Low Range Portable Total Dissolved Solids (TDS) Meter","description":"\u003ch2 data-section-id=\"7ol1dc\" data-start=\"179\" data-end=\"246\" class=\"PDq2pG_selectionAnchorContainer\"\u003eMilwaukee MW401 PRO Low Range Total Dissolved Solids (TDS) Meter\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"248\" data-end=\"700\"\u003eThe Milwaukee MW401 PRO Total Dissolved Solids (TDS) Meter is a reliable, portable instrument designed for fast and accurate measurement of total dissolved solids (TDS) in water. Featuring automatic temperature compensation (ATC), a professional SE510 conductivity probe, and an easy-to-read LCD display, the MW401 is ideal for laboratories, aquariums, aquaculture, water treatment, food processing, and water conditioning applications.\u003c\/p\u003e\n\u003cp data-start=\"702\" data-end=\"1047\"\u003eAccurate measurement of dissolved solids helps improve water quality, optimize treatment processes, and reduce operating costs. Whether monitoring drinking water, nutrient solutions, aquariums, or industrial water systems, the MW401 delivers dependable readings in a lightweight, easy-to-use design suitable for both professionals and hobbyists.\u003c\/p\u003e\n\u003cp data-start=\"1049\" data-end=\"1215\"\u003eSupplied complete with the \u003cstrong data-start=\"1076\" data-end=\"1104\"\u003eSE510 conductivity probe\u003c\/strong\u003e, a \u003cstrong data-start=\"1108\" data-end=\"1141\"\u003e1382 ppm calibration solution\u003c\/strong\u003e, and a long-life battery, the Milwaukee MW401 is ready for immediate use.\u003c\/p\u003e\n\u003chr data-start=\"1217\" data-end=\"1220\"\u003e\n\u003ch2 data-section-id=\"4coekx\" data-start=\"1222\" data-end=\"1260\"\u003eWhy Measure Total Dissolved Solids?\u003c\/h2\u003e\n\u003cp data-start=\"1262\" data-end=\"1488\"\u003eTotal Dissolved Solids (TDS) represent the concentration of dissolved minerals, salts, and other substances present in water. Monitoring TDS helps maintain water quality and improve system performance across many applications.\u003c\/p\u003e\n\u003cp data-start=\"1490\" data-end=\"1514\"\u003eCommon benefits include:\u003c\/p\u003e\n\u003cul data-start=\"1516\" data-end=\"1765\"\u003e\n\u003cli data-section-id=\"1cuksme\" data-start=\"1516\" data-end=\"1551\"\u003eMonitoring drinking water quality\u003c\/li\u003e\n\u003cli data-section-id=\"qml237\" data-start=\"1552\" data-end=\"1588\"\u003eOptimizing water treatment systems\u003c\/li\u003e\n\u003cli data-section-id=\"1e6oemd\" data-start=\"1589\" data-end=\"1623\"\u003eManaging nutrient concentrations\u003c\/li\u003e\n\u003cli data-section-id=\"ovlr8v\" data-start=\"1624\" data-end=\"1667\"\u003eImproving aquarium and aquaculture health\u003c\/li\u003e\n\u003cli data-section-id=\"19ydlyq\" data-start=\"1668\" data-end=\"1699\"\u003eSupporting laboratory testing\u003c\/li\u003e\n\u003cli data-section-id=\"umdz1o\" data-start=\"1700\" data-end=\"1731\"\u003eReducing chemical consumption\u003c\/li\u003e\n\u003cli data-section-id=\"1p9ktec\" data-start=\"1732\" data-end=\"1765\"\u003eMaintaining process consistency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1767\" data-end=\"1770\"\u003e\n\u003ch2 data-section-id=\"3ipjz4\" data-start=\"1772\" data-end=\"1797\"\u003eProduct Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1799\" data-end=\"2523\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1799\" data-end=\"1826\"\u003e\n\u003ctr data-start=\"1799\" data-end=\"1826\"\u003e\n\u003cth data-start=\"1799\" data-end=\"1815\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1815\" data-end=\"1826\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1854\" data-end=\"2523\"\u003e\n\u003ctr data-start=\"1854\" data-end=\"1894\"\u003e\n\u003ctd data-start=\"1854\" data-end=\"1869\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-start=\"1869\" data-end=\"1894\" data-col-size=\"md\"\u003eMilwaukee Instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1895\" data-end=\"1916\"\u003e\n\u003ctd data-start=\"1895\" data-end=\"1903\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1903\" data-end=\"1916\" data-col-size=\"md\"\u003eMW401 PRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1917\" data-end=\"1979\"\u003e\n\u003ctd data-start=\"1917\" data-end=\"1932\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"1932\" data-end=\"1979\" data-col-size=\"md\"\u003ePortable Total Dissolved Solids (TDS) Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1980\" data-end=\"2021\"\u003e\n\u003ctd data-start=\"1980\" data-end=\"2000\" data-col-size=\"sm\"\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd data-start=\"2000\" data-end=\"2021\" data-col-size=\"md\"\u003e0–1990 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2022\" data-end=\"2051\"\u003e\n\u003ctd data-start=\"2022\" data-end=\"2035\" data-col-size=\"sm\"\u003eResolution\u003c\/td\u003e\n\u003ctd data-start=\"2035\" data-end=\"2051\" data-col-size=\"md\"\u003e1 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2052\" data-end=\"2088\"\u003e\n\u003ctd data-start=\"2052\" data-end=\"2063\" data-col-size=\"sm\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-start=\"2063\" data-end=\"2088\" data-col-size=\"md\"\u003e±2% Full Scale @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2089\" data-end=\"2121\"\u003e\n\u003ctd data-start=\"2089\" data-end=\"2113\" data-col-size=\"sm\"\u003eTDS Conversion Factor\u003c\/td\u003e\n\u003ctd data-start=\"2113\" data-end=\"2121\" data-col-size=\"md\"\u003e0.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2122\" data-end=\"2182\"\u003e\n\u003ctd data-start=\"2122\" data-end=\"2149\" data-col-size=\"sm\"\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd data-start=\"2149\" data-end=\"2182\" data-col-size=\"md\"\u003eAutomatic (5–50°C \/ 41–122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2183\" data-end=\"2228\"\u003e\n\u003ctd data-start=\"2183\" data-end=\"2200\" data-col-size=\"sm\"\u003eIncluded Probe\u003c\/td\u003e\n\u003ctd data-start=\"2200\" data-end=\"2228\" data-col-size=\"md\"\u003eSE510 Conductivity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2229\" data-end=\"2266\"\u003e\n\u003ctd data-start=\"2229\" data-end=\"2250\" data-col-size=\"sm\"\u003eProbe Cable Length\u003c\/td\u003e\n\u003ctd data-start=\"2250\" data-end=\"2266\" data-col-size=\"md\"\u003e1 m (3.3 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2267\" data-end=\"2328\"\u003e\n\u003ctd data-start=\"2267\" data-end=\"2299\" data-col-size=\"sm\"\u003eCalibration Solution Included\u003c\/td\u003e\n\u003ctd data-start=\"2299\" data-end=\"2328\" data-col-size=\"md\"\u003eMI0032B 1382 ppm Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2329\" data-end=\"2358\"\u003e\n\u003ctd data-start=\"2329\" data-end=\"2339\" data-col-size=\"sm\"\u003eBattery\u003c\/td\u003e\n\u003ctd data-start=\"2339\" data-end=\"2358\" data-col-size=\"md\"\u003e1 × 9V Alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2359\" data-end=\"2401\"\u003e\n\u003ctd data-start=\"2359\" data-end=\"2374\" data-col-size=\"sm\"\u003eBattery Life\u003c\/td\u003e\n\u003ctd data-start=\"2374\" data-end=\"2401\" data-col-size=\"md\"\u003eApproximately 300 Hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2402\" data-end=\"2447\"\u003e\n\u003ctd data-start=\"2402\" data-end=\"2426\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2426\" data-end=\"2447\" data-col-size=\"md\"\u003e0–50°C (32–122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2448\" data-end=\"2487\"\u003e\n\u003ctd data-start=\"2448\" data-end=\"2467\" data-col-size=\"sm\"\u003eMeter Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"2467\" data-end=\"2487\" data-col-size=\"md\"\u003e143 × 80 × 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2488\" data-end=\"2523\"\u003e\n\u003ctd data-start=\"2488\" data-end=\"2503\" data-col-size=\"sm\"\u003eMeter Weight\u003c\/td\u003e\n\u003ctd data-start=\"2503\" data-end=\"2523\" data-col-size=\"md\"\u003e0.23 kg (0.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2525\" data-end=\"2528\"\u003e\n\u003ch2 data-section-id=\"gh0k9s\" data-start=\"2530\" data-end=\"2552\"\u003eFeatures \u0026amp; Benefits\u003c\/h2\u003e\n\u003ch3 data-section-id=\"14a71iq\" data-start=\"2554\" data-end=\"2592\"\u003eAccurate Low Range TDS Measurement\u003c\/h3\u003e\n\u003cp data-start=\"2594\" data-end=\"2745\"\u003eMeasures dissolved solids from \u003cstrong data-start=\"2625\" data-end=\"2649\"\u003e0 to 1990 mg\/L (ppm)\u003c\/strong\u003e with \u003cstrong data-start=\"2655\" data-end=\"2675\"\u003e1 ppm resolution\u003c\/strong\u003e, making it suitable for a wide variety of water quality applications.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1nx8ano\" data-start=\"2747\" data-end=\"2791\"\u003eAutomatic Temperature Compensation (ATC)\u003c\/h3\u003e\n\u003cp data-start=\"2793\" data-end=\"2882\"\u003eAutomatically compensates measurements for water temperature to improve testing accuracy.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1u6ga2o\" data-start=\"2884\" data-end=\"2928\"\u003eProfessional Conductivity Probe Included\u003c\/h3\u003e\n\u003cp data-start=\"2930\" data-end=\"3042\"\u003eSupplied with the \u003cstrong data-start=\"2948\" data-end=\"2986\"\u003eMilwaukee SE510 conductivity probe\u003c\/strong\u003e featuring a \u003cstrong data-start=\"2999\" data-end=\"3017\"\u003e3.3-foot cable\u003c\/strong\u003e for convenient sampling.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1glcz56\" data-start=\"3044\" data-end=\"3065\"\u003eLarge LCD Display\u003c\/h3\u003e\n\u003cp data-start=\"3067\" data-end=\"3165\"\u003eEasy-to-read digital display provides clear measurement values for both field and laboratory work.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1xcdtu5\" data-start=\"3167\" data-end=\"3193\"\u003ePortable \u0026amp; Lightweight\u003c\/h3\u003e\n\u003cp data-start=\"3195\" data-end=\"3308\"\u003eCompact design makes the MW401 easy to carry between sampling locations while remaining durable for everyday use.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1370f47\" data-start=\"3310\" data-end=\"3331\"\u003eLong Battery Life\u003c\/h3\u003e\n\u003cp data-start=\"3333\" data-end=\"3406\"\u003eOperates for approximately \u003cstrong data-start=\"3360\" data-end=\"3373\"\u003e300 hours\u003c\/strong\u003e on a single 9V alkaline battery.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1u8a54l\" data-start=\"3408\" data-end=\"3424\"\u003eReady to Use\u003c\/h3\u003e\n\u003cp data-start=\"3426\" data-end=\"3524\"\u003eIncludes a \u003cstrong data-start=\"3437\" data-end=\"3470\"\u003e1382 ppm calibration solution\u003c\/strong\u003e so users can calibrate the instrument before testing.\u003c\/p\u003e\n\u003chr data-start=\"3526\" data-end=\"3529\"\u003e\n\u003ch2 data-section-id=\"19vd27d\" data-start=\"3531\" data-end=\"3552\"\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp data-start=\"3554\" data-end=\"3591\"\u003eThe Milwaukee MW401 PRO is ideal for:\u003c\/p\u003e\n\u003cul data-start=\"3593\" data-end=\"3855\"\u003e\n\u003cli data-section-id=\"1ll3cs1\" data-start=\"3593\" data-end=\"3617\"\u003eDrinking water testing\u003c\/li\u003e\n\u003cli data-section-id=\"v859ql\" data-start=\"3618\" data-end=\"3642\"\u003eWater treatment plants\u003c\/li\u003e\n\u003cli data-section-id=\"fnb6ag\" data-start=\"3643\" data-end=\"3671\"\u003eWater conditioning systems\u003c\/li\u003e\n\u003cli data-section-id=\"1yb07s9\" data-start=\"3672\" data-end=\"3697\"\u003eReverse osmosis systems\u003c\/li\u003e\n\u003cli data-section-id=\"v1hrp8\" data-start=\"3698\" data-end=\"3709\"\u003eAquariums\u003c\/li\u003e\n\u003cli data-section-id=\"p02ge8\" data-start=\"3710\" data-end=\"3723\"\u003eAquaculture\u003c\/li\u003e\n\u003cli data-section-id=\"6dow6g\" data-start=\"3724\" data-end=\"3737\"\u003eHydroponics\u003c\/li\u003e\n\u003cli data-section-id=\"1pzpf6p\" data-start=\"3738\" data-end=\"3755\"\u003eFood processing\u003c\/li\u003e\n\u003cli data-section-id=\"1t7yivi\" data-start=\"3756\" data-end=\"3777\"\u003eBeverage production\u003c\/li\u003e\n\u003cli data-section-id=\"1m89z0c\" data-start=\"3778\" data-end=\"3804\"\u003eEnvironmental monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"tuv45w\" data-start=\"3805\" data-end=\"3828\"\u003eResearch laboratories\u003c\/li\u003e\n\u003cli data-section-id=\"1lr07fs\" data-start=\"3829\" data-end=\"3855\"\u003eEducational institutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3857\" data-end=\"3860\"\u003e\n\u003ch2 data-section-id=\"5beslv\" data-start=\"3862\" data-end=\"3881\"\u003eWhy Monitor TDS?\u003c\/h2\u003e\n\u003ch3 data-section-id=\"4f8z7o\" data-start=\"3883\" data-end=\"3908\"\u003eImprove Water Quality\u003c\/h3\u003e\n\u003cp data-start=\"3910\" data-end=\"4005\"\u003eRoutine TDS testing helps identify changes in water quality before they become larger problems.\u003c\/p\u003e\n\u003ch3 data-section-id=\"7l2e5q\" data-start=\"4007\" data-end=\"4035\"\u003eOptimize Water Treatment\u003c\/h3\u003e\n\u003cp data-start=\"4037\" data-end=\"4142\"\u003eMonitoring dissolved solids allows operators to improve filtration efficiency and reduce treatment costs.\u003c\/p\u003e\n\u003ch3 data-section-id=\"37mjsw\" data-start=\"4144\" data-end=\"4179\"\u003eSupport Healthy Aquatic Systems\u003c\/h3\u003e\n\u003cp data-start=\"4181\" data-end=\"4290\"\u003eMaintaining proper TDS levels promotes healthier conditions for fish, aquatic plants, and other aquatic life.\u003c\/p\u003e\n\u003ch3 data-section-id=\"mqpmlv\" data-start=\"4292\" data-end=\"4325\"\u003eVerify Drinking Water Quality\u003c\/h3\u003e\n\u003cp data-start=\"4327\" data-end=\"4421\"\u003eTDS measurements help evaluate the effectiveness of filtration and water conditioning systems.\u003c\/p\u003e\n\u003chr data-start=\"4423\" data-end=\"4426\"\u003e\n\u003ch2 data-section-id=\"1k9og2c\" data-start=\"4428\" data-end=\"4456\"\u003eCalibration \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp data-start=\"4458\" data-end=\"4479\"\u003eFor best performance:\u003c\/p\u003e\n\u003cul data-start=\"4481\" data-end=\"4744\"\u003e\n\u003cli data-section-id=\"b6qvk4\" data-start=\"4481\" data-end=\"4563\"\u003eCalibrate regularly using \u003cstrong data-start=\"4509\" data-end=\"4562\"\u003e1382 ppm calibration solution (MI0032B or MA9062)\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli data-section-id=\"1e528r0\" data-start=\"4564\" data-end=\"4614\"\u003eRinse the probe with clean water after each use.\u003c\/li\u003e\n\u003cli data-section-id=\"10pk1e3\" data-start=\"4615\" data-end=\"4669\"\u003eStore the probe clean and protected when not in use.\u003c\/li\u003e\n\u003cli data-section-id=\"jqz31f\" data-start=\"4670\" data-end=\"4744\"\u003eReplace calibration solution regularly to maintain measurement accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4746\" data-end=\"4846\"\u003eRoutine calibration ensures the meter continues to provide accurate and repeatable TDS measurements.\u003c\/p\u003e\n\u003chr data-start=\"4848\" data-end=\"4851\"\u003e\n\u003ch2 data-section-id=\"1r8frcv\" data-start=\"4853\" data-end=\"4882\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3 data-section-id=\"6csog0\" data-start=\"4884\" data-end=\"4916\"\u003eWhat does the MW401 measure?\u003c\/h3\u003e\n\u003cp data-start=\"4918\" data-end=\"4979\"\u003eThe MW401 measures \u003cstrong data-start=\"4937\" data-end=\"4969\"\u003eTotal Dissolved Solids (TDS)\u003c\/strong\u003e in water.\u003c\/p\u003e\n\u003ch3 data-section-id=\"r72zmt\" data-start=\"4981\" data-end=\"5015\"\u003eWhat is the measurement range?\u003c\/h3\u003e\n\u003cp data-start=\"5017\" data-end=\"5066\"\u003eThe meter measures from \u003cstrong data-start=\"5041\" data-end=\"5065\"\u003e0 to 1990 mg\/L (ppm)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"10cdwae\" data-start=\"5068\" data-end=\"5109\"\u003eWhat accuracy does the MW401 provide?\u003c\/h3\u003e\n\u003cp data-start=\"5111\" data-end=\"5171\"\u003eThe instrument provides \u003cstrong data-start=\"5135\" data-end=\"5170\"\u003e±2% Full Scale accuracy at 25°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1onfq65\" data-start=\"5173\" data-end=\"5233\"\u003eDoes the meter automatically compensate for temperature?\u003c\/h3\u003e\n\u003cp data-start=\"5235\" data-end=\"5325\"\u003eYes. The MW401 features \u003cstrong data-start=\"5259\" data-end=\"5303\"\u003eAutomatic Temperature Compensation (ATC)\u003c\/strong\u003e from \u003cstrong data-start=\"5309\" data-end=\"5324\"\u003e5°C to 50°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"wwpk7k\" data-start=\"5327\" data-end=\"5351\"\u003eIs a probe included?\u003c\/h3\u003e\n\u003cp data-start=\"5353\" data-end=\"5454\"\u003eYes. The meter includes the \u003cstrong data-start=\"5381\" data-end=\"5419\"\u003eMilwaukee SE510 conductivity probe\u003c\/strong\u003e with a \u003cstrong data-start=\"5427\" data-end=\"5453\"\u003e1 metre (3.3 ft) cable\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"bjm7uw\" data-start=\"5456\" data-end=\"5493\"\u003eIs calibration solution included?\u003c\/h3\u003e\n\u003cp data-start=\"5495\" data-end=\"5585\"\u003eYes. The MW401 includes \u003cstrong data-start=\"5519\" data-end=\"5560\"\u003eMI0032B 1382 ppm calibration solution\u003c\/strong\u003e for initial calibration.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1s55fk\" data-start=\"5587\" data-end=\"5622\"\u003eHow long does the battery last?\u003c\/h3\u003e\n\u003cp data-start=\"5624\" data-end=\"5705\"\u003eThe meter operates for approximately \u003cstrong data-start=\"5661\" data-end=\"5674\"\u003e300 hours\u003c\/strong\u003e using one 9V alkaline battery.\u003c\/p\u003e\n\u003ch3 data-section-id=\"28ugt2\" data-start=\"5707\" data-end=\"5742\"\u003eWho is this meter designed for?\u003c\/h3\u003e\n\u003cp data-start=\"5744\" data-end=\"5940\"\u003eThe MW401 is suitable for water treatment professionals, laboratories, aquaculture operations, aquarium owners, hydroponic growers, food processing facilities, and anyone monitoring water quality.\u003c\/p\u003e","brand":"Milwaukee Instruments","offers":[{"title":"Default Title","offer_id":53989715476844,"sku":"MW401","price":387.44,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/MW401-Incl__67097.1602021295_1.jpg?v=1783100590","url":"https:\/\/cleanflow.net\/products\/milwaukee-mw401-pro-low-range-portable-total-dissolved-solids-tds-meter","provider":"Cleanflow","version":"1.0","type":"link"}