{"product_id":"ptp150-unit-heater-w-st-steel-heat-exchanger-ng-150-000-btu","title":"Modine PTP300 Horizontal Power-Vented Natural Gas Unit Heater - 300,000 BTU, 115V, Aluminized Steel","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003e300,000 BTU Commercial Natural Unit Heater With 4,545 CFM, 69-Foot Heat Throw, And 19-Foot Mounting Height\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eModine PTP300 (PTP300AS0111)\u003c\/strong\u003e is a 300,000 BTU commercial gas unit heater \u003c\/span\u003e\u003cspan\u003eengineered for large commercial and industrial spaces. At 300,000 BTU input and 249,000 BTU output (83% efficiency), it pushes 4,545 CFM with a 50°F temperature rise and throws heat 69 feet from a maximum mounting height of 19 feet. The 1\/2 HP motor drives an 824 FPM outlet velocity through a 22-inch propeller fan, covering large open floor plans that require high-volume air delivery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe PTP300 is a 300,000 BTU commercial unit heater built on the same 6-inch vent and 3\/4-inch gas infrastructure as the rest of the PTP 250-400 range. It features a tubular heat exchanger with in-shot burners, a 20-gauge aluminized steel cabinet, in-cabinet controls protection, and a contractor convenience box with diagnostic LEDs. The 409 stainless steel heat exchanger option carries a 10-year warranty that includes greenhouse use.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eQuick Specs\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eBTU Input:\u003c\/strong\u003e\u003cspan\u003e 300,000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eBTU Output:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003e249,000 (83% efficiency)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eAirflow:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003e4,545 CFM at 70°F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e\u003cspan\u003e 115V, 1-Phase, 60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eVent Size:\u003c\/strong\u003e\u003cspan\u003e 6 inch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eGas Connection:\u003c\/strong\u003e\u003cspan\u003e 3\/4 inch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eMaximum Mounting Height:\u003c\/strong\u003e\u003cspan\u003e 19 ft\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eHeat Throw:\u003c\/strong\u003e\u003cspan\u003e 69 ft at max mounting height\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eDimensions (D x W x H):\u003c\/strong\u003e\u003cspan\u003e 33.83 x 42.53 x 31.31 inches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e 270 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003e300,000 BTU with 4,545 CFM and 69-foot throw:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eThis 300,000 BTU commercial gas unit heater delivers 249,000 BTU of usable output across expansive floor plans. The 69-foot heat throw from a 19-foot mounting height reaches the far corners of warehouses, factories, and industrial bays.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003e1\/2 HP motor:\u003c\/strong\u003e\u003cspan\u003e The PTP300 unit heater uses a 1\/2 HP PSC motor at 1,075 RPM, driving 4,545 CFM through a 22-inch propeller fan at 824 FPM outlet velocity. This is the motor tier for high-volume air delivery across large open spaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003e6-inch power-vented exhaust:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eFactory-installed power exhauster handles horizontal vent runs up to 70 feet. 6-inch vent pipe with 3\/4-inch gas connection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eTubular heat exchanger with in-shot burners:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eEach heat exchanger tube has its own in-shot burner for consistent combustion and heat transfer. This design extends exchanger life and improves efficiency over drum-style exchangers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003e409 stainless steel heat exchanger available:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eStandard aluminized steel handles most commercial environments. The stainless option (PTP300SS0111) is rated for greenhouses, agricultural buildings, and corrosive atmospheres. Both carry a 10-year warranty.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eIn-cabinet controls protection:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eControls, power exhauster, and ignition components are sealed inside the cabinet, shielded from dust, moisture, and debris in harsh commercial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eContractor convenience box:\u003c\/strong\u003e\u003cspan\u003e On\/off toggle switch, green power indicator, yellow call-for-heat indicator, terminal board for low-voltage wiring, and conduit knockouts. Diagnostic LEDs for on-site troubleshooting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eLow-profile horizontal design:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eCeiling or wall mount. The 42.53-inch width fits standard commercial joist spacing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eField convertible to propane:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eShips natural gas. Propane conversion available per Modine Manual 75-515. Natural gas consumption: 285.7 CFH at 3.5\" W.C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eCold climate rated:\u003c\/strong\u003e\u003cspan\u003e Starts at -40°F. ETL certified for commercial and industrial use in the US and Canada. CSA-B149.1 compliant.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eModine PTP300 Natural Gas Commercial Unit Heater Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv dir=\"ltr\" align=\"left\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"271\"\u003e \u003ccol width=\"353\"\u003e \u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eModine\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePTP (Horizontal Power-Vented, Propeller Fan)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePTP300\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePTP300AS0111 (Natural Gas, Aluminized Steel, 115V, Direct Spark, Single-Stage)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFuel Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNatural Gas (field convertible to Propane)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBTU\/hr Input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e300,000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBTU\/hr Output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e249,000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThermal Efficiency\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e83%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e115V, 1-Phase, 60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eControl Voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e24V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eEntering Airflow (CFM)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e4,545 at 70°F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOutlet Velocity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e824 FPM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAir Temperature Rise\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e50°F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHeat Throw\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e69 ft at max mounting height\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMaximum Mounting Height\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e19 ft\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFan Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e22-inch Propeller, Totally Enclosed Motor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMotor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePSC, 1\/2 HP, 1,075 RPM, permanently lubricated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBurner Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIn-Shot (one per heat exchanger tube, 9 orifices)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOrifice Drill Size (NG)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e#39\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOrifice Drill Size (LP)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1.55mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eVent Connector Size\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e6 inch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMax Horizontal Vent Length\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e70 ft\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eGas Connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e3\/4 inch NPT\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eGas Consumption (NG)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e285.7 CFH at 3.5\" W.C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eGas Consumption (LP)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e3.3 gal\/hr at 10\" W.C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIgnition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDirect Spark, 100% Shut-Off, Continuous Retry (Two-Stage available: 100%\/50% firing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHeat Exchanger\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTubular, Aluminized Steel (standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCabinet Material\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e20 ga Aluminized Steel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFinish\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBaked-On Polyester Powder Paint, neutral color\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHeat Exchanger Warranty\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e10 years (includes greenhouse use)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eParts Warranty\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e2 years\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSheet Metal Warranty\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1 year\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDimensions (D x W x H)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e33.83 x 42.53 x 31.31 inches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e270 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eClearance to Combustibles (Top\/Bottom)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e6 inches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eClearance to Combustibles (Sides)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e6 inches (both sides)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eClearance to Combustibles (Rear)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e18 inches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eClearance to Vent Connector\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e6 inches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMin. Install Height (Commercial)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e7 ft from floor (bottom of unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOperating Ambient Range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e-40°F to 90°F (startup), 40°F to 90°F (operating)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eETL Listed (Intertek), CEC (California), Massachusetts approved\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eApplicable Standards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eANSI Z223.1 (NFPA 54), CSA-B149.1, ANSI\/NFPA 70\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePropane Conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eField convertible per Modine Manual 75-515\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCountry of Manufacture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eAvailable Options\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eFuel Type:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eNatural Gas (standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003ePropane (field convertible per Modine Manual 75-515)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eIgnition Type:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eSingle-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry (standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eTwo-Stage, Direct Spark Ignition (optional, fires at 100% and 50% of rated input)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eHeat Exchanger Material:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eTubular, Aluminized Steel (standard, this model: PTP300AS0111)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eTubular, 409 Stainless Steel (optional, model: PTP300SS0111, rated for greenhouses and corrosive environments)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eFan Configuration:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003ePropeller Fan (PTP series, this model)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eCentrifugal Blower Fan (BTP series, for ducted applications)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003ePerformance Overview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe PTP300 unit heater delivers 4,545 CFM at a 50°F temperature rise with an 824 FPM outlet velocity, producing 249,000 BTU of usable heat output. From its 19-foot maximum mounting height, it throws heat 69 feet across the floor. The 1\/2 HP motor and 22-inch propeller fan handle the air volume that large warehouses, distribution centers, and factory floors demand. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAs a 300,000 BTU natural gas power vented industrial heater, the PTP300 operates on a 6-inch vent pipe with horizontal runs up to 70 feet and a 3\/4-inch gas connection. The 300,000 BTU commercial unit heater is rated for spaces approximately 8,000 to 10,000+ square feet, depending on insulation, ceiling height, and climate zone.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eIncluded with the PTP300\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eAdjustable horizontal air deflector blades\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eFactory-installed power exhauster (6-inch)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eContractor convenience box (toggle switch, diagnostic LEDs, terminal board)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eGas control step-down transformer (24V)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eFan delay timer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eAuto-reset limit control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eDifferential pressure switch (proof of venting)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eInstallation and service manual\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eNot included (sold separately):\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eVent pipe and fittings (6-inch diameter required)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eVent cap (Modine PN 5H0722850002 for PTP250-400)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eThermostat (any standard 24V thermostat)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003ePropane conversion kit (per Modine Manual 75-515)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eGas supply piping and shutoff valve (3\/4-inch)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eDeflector hoods (30, 60, and 90-degree available)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eVibration isolation kit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eTwo-point suspension kit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eLarge warehouses and distribution centers (8,000 to 10,000+ sq ft)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eManufacturing floors and factory bays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eGreenhouses and agricultural buildings (stainless steel heat exchanger recommended)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eAuto dealership service departments and fleet garages\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eAircraft hangars (minimum 10 ft above the highest wing or engine surface)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eLoading docks, freight terminals, and cold storage staging areas\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eFire stations, transit maintenance facilities, and municipal buildings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eInstallation Tips\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eCommercial and industrial use only.\u003c\/strong\u003e\u003cspan\u003e The PTP series is ETL certified for commercial and industrial applications. It is not certified for residential use.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003e6-inch vent pipe and 3\/4-inch gas required.\u003c\/strong\u003e\u003cspan\u003e Same infrastructure as the PTP250. If you are upgrading from a PTP250, no vent or gas line changes are needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eMax 70-foot horizontal vent run.\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eEach 90-degree elbow adds equivalent length. Minimum 3-foot vent run required.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003e270 lbs shipping weight.\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003ePlan for appropriate rigging and ceiling structure support. Two-point suspension kit available as an accessory.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eHigh altitude derating.\u003c\/strong\u003e\u003cspan\u003e For elevations above 2,000 feet, reduce ratings by 4% per 1,000 feet above sea level.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eClearances:\u003c\/strong\u003e\u003cspan\u003e 6 inches on all sides (top, bottom, access, non-access). 18 inches at the rear. Minimum 7-foot install height from floor. In aircraft hangars, a minimum of 10 feet above the highest wing or engine surface.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eBuy the Modine PTP300 Commercial Gas Unit Heater Online from Cleanflow\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe PTP300 is a 300,000 BTU commercial gas unit heater with the output, airflow, and throw distance to handle large warehouses and industrial facilities. The 1\/2 HP motor, 4,545 CFM airflow, and 69-foot heat throw cover floor areas that most commercial heaters in this class cannot reach from a single unit. The tubular heat exchanger with in-shot burners, in-cabinet controls protection, and a 10-year warranty (including greenhouse use) is standard. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003ca href=\"https:\/\/cleanflow.net\/\"\u003e\u003cspan\u003eCleanflow Utility Supply Company\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e stocks the PTP300 unit heater with free shipping on orders over $199 CAD across Canada and the USA. As an authorized Modine supplier, Cleanflow backs every unit with manufacturer warranty support. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNot the right fit? Cleanflow offers hassle-free \u003c\/span\u003e\u003ca href=\"https:\/\/returns.cleanflow.net\/\"\u003e\u003cspan\u003ereturns and exchanges\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e on all orders.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eHow many square feet will the PTP300 heat?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAt 300,000 BTU input (249,000 BTU output), the PTP300 unit heater handles approximately 8,000 to 10,000+ square feet, depending on insulation, ceiling height, and climate zone. The 69-foot heat throw from a 19-foot mounting height covers large open floor plans. For buildings over 10,000 square feet, multiple units or a larger PTP model may be needed.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eWhat are the PTP300's advantages over other 300,000 BTU heaters?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe PTP300 unit heater features a tubular heat exchanger with in-shot burners, in-cabinet controls, protection that seals wiring and ignition components from dust and moisture, a contractor convenience box with diagnostic LEDs, and a 409 stainless steel heat exchanger option with a 10-year warranty, including greenhouse use. It is designed, engineered, and assembled in the USA. These are verifiable specs from Modine's product documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eDoes the PTP300 require a 6-inch vent pipe?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes. The PTP300 unit heater uses a 6-inch vent pipe and a 3\/4-inch gas connection with a maximum horizontal vent run of 70 feet. If you are upgrading from a PTP250, the same vent pipe and gas line work.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eCan the PTP300 commercial unit heater run on propane?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes. Ships natural gas. Field convertible to propane per Modine Manual 75-515. Propane consumption is 3.3 gallons per hour at 10\" W.C. manifold pressure. The unit uses 9 orifices; drill size changes from #39 (NG) to 1.55mm (LP).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eIs the PTP300 unit heater rated for cold climates like Canada?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes. Starts at -40°F. ETL certified for commercial and industrial use in the US and Canada. CSA-B149.1 compliant. At 300,000 BTU input, it provides substantial heating for large commercial and industrial spaces in extreme cold. For elevations above 2,000 feet, derate by 4% per 1,000 feet.\u003c\/span\u003e\u003c\/p\u003e","brand":"Modine","offers":[{"title":"Default Title","offer_id":53776346710380,"sku":"PTP300AS0111","price":5473.04,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/PTP300AS_Horizontal_Power-Vented_Gas-Fired_Unit_Heater.webp?v=1779283235","url":"https:\/\/cleanflow.net\/products\/ptp150-unit-heater-w-st-steel-heat-exchanger-ng-150-000-btu","provider":"Cleanflow","version":"1.0","type":"link"}