{"product_id":"ptp300-unit-heater-w-st-steel-heat-exchanger-ng-300-000-btu","title":"Modine PTP200 Horizontal Power-Vented Natural Gas Unit Heater - 200,000 BTU, 115V, Aluminized Steel","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eThe Most Powerful PTP On 4-Inch Venting: 200,000 BTU Commercial-Grade Low-Profile Natural Gas Unit Heater For Warehouses, Workshops, And Large Commercial Spaces\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eModine PTP200 (PTP200AS0111)\u003c\/strong\u003e commercial gas unit heater\u003c\/span\u003e\u003cspan\u003e is the largest and most powerful model in the PTP series that still uses a 4-inch vent pipe. At 200,000 BTU input and 164,000 BTU output (82% efficiency), it pushes 2,870 CFM with a 52°F temperature rise and throws heat 53 feet from a maximum mounting height of 15 feet. The PTP250 and above require 6-inch venting. If you need maximum output on a 4-inch pipe, the PTP200 is the ceiling.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe PTP200 natural gas unit heater also steps up to a 1\/3 HP motor, double the 1\/6 HP used on the \u003c\/span\u003e\u003cspan\u003ePTP150 \u003c\/span\u003e\u003cspan\u003eand \u003c\/span\u003e\u003cspan\u003ePTP175\u003c\/span\u003e\u003cspan\u003e. This drives 2,870 CFM through the same 22-inch propeller fan at a higher outlet velocity (643 FPM vs 607 on the PTP175), delivering a longer heat throw (53 ft vs 50 ft) from a higher mounting point (15 ft vs 14 ft). \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eLike all PTP models, it features a 20-gauge aluminized steel cabinet, a contractor convenience box with diagnostic LEDs, and controls protected inside the cabinet.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eQuick Specs\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eBTU Input:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003e200,000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eBTU Output:\u003c\/strong\u003e\u003cspan\u003e 164,000 (82% efficiency)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eAirflow:\u003c\/strong\u003e\u003cspan\u003e 2,870 CFM at 70°F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e\u003cspan\u003e 115V, 1-Phase, 60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eVent Size:\u003c\/strong\u003e\u003cspan\u003e 4 inch (last PTP model before 6-inch)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eMaximum Mounting Height:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003e15 ft\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eHeat Throw:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003e53 ft at max mounting height\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eDimensions (D x W x H):\u003c\/strong\u003e\u003cspan\u003e 34.43 x 42.53 x 25.81 inches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003e220 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003e200,000 BTU with 2,870 CFM:\u003c\/strong\u003e\u003cspan\u003e The most powerful 200,000 BTU commercial unit heater in the PTP series on a 4-inch vent pipe. 14% more BTU than the PTP175 (175,000) and 33% more than the PTP150 (150,000).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003e1\/3 HP motor upgrade:\u003c\/strong\u003e\u003cspan\u003e The PTP200 unit heater doubles the motor from 1\/6 HP (PTP150\/PTP175) to 1\/3 HP. This drives the higher airflow (2,870 vs 2,725 CFM), higher outlet velocity (643 vs 607 FPM), longer throw (53 vs 50 ft), and higher mounting height (15 vs 14 ft).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eLast model on 4-inch vent:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eThe PTP150, PTP175, and PTP200 all use a 4-inch vent pipe and a 1\/2-inch gas connection. The PTP250 steps up to a 6-inch vent and a 3\/4-inch gas. If you want to maximize output without changing your vent infrastructure, the PTP200 unit heater is the top of the 4-inch group.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eContractor convenience box:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eBuilt-in on\/off toggle switch, green power indicator, yellow call-for-heat indicator, terminal board for low-voltage control wiring, and supply conduit power entry knockouts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eIn-cabinet controls protection:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eControls, power exhauster, and ignition components are housed inside the cabinet, shielded from airborne dust, moisture, and debris.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eLow-profile horizontal design:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eMounts to the ceiling or wall in tight commercial spaces. Same 42.53-inch width as PTP175, slightly deeper at 34.43 inches.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003e20-gauge aluminized steel cabinet:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eHeavier gauge than the HD series (22-gauge). Built for commercial and industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003e10-year heat exchanger warranty:\u003c\/strong\u003e\u003cspan\u003e Aluminized steel tubular design standard. 409 stainless steel is available for greenhouses and corrosive environments (10-year warranty includes greenhouse use).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eConverts to propane:\u003c\/strong\u003e\u003cspan\u003e Ships natural gas. Modine kit #55405 converts to LP. The same burner is used for both fuels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eCold climate rated:\u003c\/strong\u003e\u003cspan\u003e Starts reliably down to -40°F. ETL certified for commercial and industrial use in the US and Canada.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eModine PTP200 Natural Gas Commercial Unit Heater Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv dir=\"ltr\" align=\"left\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"249\"\u003e\n\u003ccol width=\"375\"\u003e\n\u003c\/colgroup\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCategory\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth scope=\"col\"\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDetails\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eModine\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePTP (Horizontal Power-Vented, Propeller Fan)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePTP200\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePTP200AS0111 (Natural Gas, Aluminized Steel, 115V, Direct Spark, Single-Stage)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFuel Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNatural Gas (field convertible to Propane)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBTU\/hr Input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e200,000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBTU\/hr Output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e164,000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThermal Efficiency\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e82%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e115V, 1-Phase, 60 Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eControl Voltage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e24V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eEntering Airflow (CFM)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e2,870 at 70°F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOutlet Velocity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e643 FPM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAir Temperature Rise\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e52°F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHeat Throw\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e53 ft at max mounting height\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMaximum Mounting Height\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e15 ft\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFan Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e22-inch Propeller, Totally Enclosed Motor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMotor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePSC, 1\/3 HP, 1,075 RPM, permanently lubricated\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBurner Type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIn-Shot (one per heat exchanger tube, 7 orifices)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eVent Connector Size\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e4 inch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMax Horizontal Vent Length\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e70 ft\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eGas Connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1\/2 inch NPT\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eGas Consumption (NG)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e190.5 CFH at 3.5\" W.C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eGas Consumption (LP)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e80.0 CFH at 10\" W.C. (2.2 gal\/hr)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIgnition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDirect Spark, 100% Shut-Off, Continuous Retry (Two-Stage available: 100%\/50% firing)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHeat Exchanger\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTubular, Aluminized Steel (standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCabinet Material\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e20 ga Aluminized Steel\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFinish\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBaked-On Polyester Powder Paint, neutral color\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eHeat Exchanger Warranty\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e10 years (includes greenhouse use)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eParts Warranty\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e2 years\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSheet Metal Warranty\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e1 year\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDimensions (D x W x H)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e34.43 x 42.53 x 25.81 inches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eShipping Weight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e220 lbs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eClearance to Combustibles (Top\/Bottom)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e6 inches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eClearance to Combustibles (Sides)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e6 inches (both sides)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eClearance to Combustibles (Rear)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e18 inches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eClearance to Vent Connector\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e6 inches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMin. Install Height (Commercial)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e7 ft from floor (bottom of unit)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOperating Ambient Range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e-40°F to 90°F (startup), 40°F to 90°F (operating)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eETL Listed (Intertek), CEC (California), Massachusetts approved\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eApplicable Standards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eANSI Z223.1 (NFPA 54), CSA-B149.1, ANSI\/NFPA 70\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eLP Conversion Kit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eModine #55405\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCountry of Manufacture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eAvailable Options\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eFuel Type:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eNatural Gas (standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003ePropane (via field conversion kit #55405)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eIgnition Type:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eSingle-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry (standard)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eTwo-Stage, Direct Spark Ignition (optional, fires at 100% and 50% of rated input)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eHeat Exchanger Material:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eTubular, Aluminized Steel (standard, this model: PTP200AS0111)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eTubular, 409 Stainless Steel (optional, model: PTP200SS0111, recommended for greenhouses)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eFan Configuration:\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003ePropeller Fan (PTP series, this model)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eCentrifugal Blower Fan (BTP series, for ducted applications)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003ePerformance Overview\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003ePTP200 Commercial Gas Unit Heater \u003c\/span\u003e\u003cspan\u003epushes 2,870 CFM at a 52°F temperature rise, delivering 164,000 BTU output from a 15-foot maximum mounting height with a 53-foot heat throw. The 1\/3 HP motor (double the PTP175's 1\/6 HP) drives the higher airflow and outlet velocity. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCompared to the PTP175, the \u003c\/span\u003e\u003cspan\u003ePTP200 unit heater\u003c\/span\u003e\u003cspan\u003e delivers 14% more BTU (200,000 vs 175,000), 5% more airflow (2,870 vs 2,725 CFM), a higher temperature rise (52°F vs 48°F), and a longer throw from a higher mount (53 ft from 15 ft vs 50 ft from 14 ft). Both use a 4-inch vent pipe with a 70-foot maximum horizontal run.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eIncluded with the Modine PTP200 Unit Heater\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eAdjustable horizontal air deflector blades\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eFactory-installed power exhauster\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eContractor convenience box (toggle switch, diagnostic LEDs, terminal board)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eGas control step-down transformer (24V)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eFan delay timer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eAuto-reset limit control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eDifferential pressure switch (proof of venting)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eInstallation and service manual\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 dir=\"ltr\"\u003e\u003cspan\u003eNot included (sold separately):\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eVent pipe and fittings (4-inch diameter required)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eVent cap (Modine PN 5H0722850001 for PTP150\/175\/200)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eThermostat (any standard 24V thermostat)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eLP conversion kit (Modine #55405)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eGas supply piping and shutoff valve\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eDeflector hoods (30, 60, and 90-degree available)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eVibration isolation kit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eTwo-point suspension kit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eMid-to-large warehouses and distribution centers (4,000 to 6,000+ sq ft)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eAuto repair shops and multi-bay service stations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eGreenhouses and agricultural buildings (stainless steel heat exchanger recommended)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eRetail stockrooms and manufacturing floors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eCommercial garages and fleet maintenance facilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eWorkshops and fabrication shops\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cspan\u003eBuildings with existing 4-inch vent infrastructure needing maximum output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eInstallation Tips\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eCommercial and industrial use only.\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eThe PTP series is ETL certified for commercial and industrial applications. It is not certified for residential use.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eLast model on the 4-inch vent.\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eThe PTP200 unit heater is the most powerful PTP with a 4-inch vent pipe and a 1\/2-inch gas connection. The PTP250 requires a 6-inch vent and 3\/4-inch gas. Choose PTP200 to maximize output on existing 4-inch infrastructure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eMax 70-foot horizontal vent run.\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eSame as PTP175. Each 90-degree elbow adds 5 feet of equivalent length. Minimum 3-foot vent run required.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eLP kit is #55405.\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eDifferent from PTP175 (#55404) and PTP150 (#55403). The same burner is used for both natural gas and propane.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eSame width as PTP175, slightly deeper.\u003c\/strong\u003e\u003cspan\u003e The Modine PTP200 unit heater is 42.53 inches wide (same as PTP175) but 34.43 inches deep (vs 32.83). Verify ceiling clearance for the added depth.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eClearances:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003e6 inches on all sides (top, bottom, access, non-access). 18 inches at the rear. Minimum 7-foot install height from floor in commercial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eBuy the Modine PTP200 Commercial Gas Unit Heater Online from Cleanflow\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIf your building already has a 4-inch vent pipe and you need every BTU you can get before a vent upgrade, the \u003c\/span\u003e\u003cspan\u003ePTP200 Unit Heater \u003c\/span\u003e\u003cspan\u003eis the answer. No other PTP model delivers 200,000 BTU on 4-inch venting. The 1\/3 HP motor and 2,870 CFM airflow handle spaces that the PTP175 cannot fully reach, and the same vent cap and gas connection mean zero infrastructure changes. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003ca href=\"https:\/\/cleanflow.net\/\"\u003e\u003cspan\u003eCleanflow Utility Supply Company\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e stocks the PTP200 Commercial Gas Unit Heater with free shipping on orders over $199 CAD across Canada and the USA. As an authorized Modine supplier, Cleanflow backs every unit with manufacturer warranty support. Not the right fit? Cleanflow offers hassle-free \u003c\/span\u003e\u003ca href=\"https:\/\/returns.cleanflow.net\/\"\u003e\u003cspan\u003ereturns and exchanges\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e on all orders.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eFrequently Asked Questions\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eHow does the PTP200 compare to the PTP175?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe PTP200 Commercial Gas Unit Heater delivers 14% more BTU (200,000 vs 175,000) and 5% more airflow (2,870 vs 2,725 CFM). It upgrades to a 1\/3 HP motor (double the PTP175's 1\/6 HP), which drives a higher outlet velocity (643 vs 607 FPM), longer throw (53 vs 50 ft), and higher max mounting height (15 vs 14 ft). Both use a 4-inch vent pipe with a 70-foot maximum horizontal run. The PTP200 is the last model before 6-inch venting. LP kit is #55405 (not PTP175's #55404).\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhy would I choose PTP200 over PTP250?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe PTP200 gas unit heater uses a 4-inch vent pipe and a 1\/2-inch gas connection. The PTP250 steps up to a 6-inch vent pipe and a 3\/4-inch gas connection. If you already have 4-inch vent infrastructure installed, the PTP200 lets you maximize output (200,000 BTU) without replacing your vent pipe. If you need more than 200,000 BTU, the PTP250 (250,000 BTU) requires the vent upgrade.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eIs the PTP200 residential-certified?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNo. At 200,000 BTU, the PTP200 is a commercial and industrial unit only. The PTP series is not ETL certified for residential installation. Residential spaces up to 125,000 BTU are covered by the Modine Hot Dawg HD series.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eCan I run the PTP200 Gas Unit Heater on the existing 4-inch vent from a smaller unit?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eYes. If you are replacing a PTP150 or PTP175, the PTP200 uses the same 4-inch vent pipe, the same vent cap (PN 5H0722850001), and the same 1\/2-inch gas connection. No vent upgrade needed. The PTP200 is the maximum output you can get before the PTP250 forces a switch to a 6-inch vent and 3\/4-inch gas.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWill 200,000 BTU heat my warehouse in a cold Canadian winter?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAt 200,000 BTU input (164,000 BTU output), the PTP200 is the best 200000 BTU commercial gas heater for a warehouse that handles approximately 4,000 to 6,000+ square feet, depending on insulation, ceiling height, and climate zone. It starts at -40°F, is ETL certified for the US and Canada, and is CSA-B149.1 compliant. For elevations above 2,000 feet, derate by 4% per 1,000 feet.\u003c\/span\u003e\u003c\/p\u003e","brand":"Modine","offers":[{"title":"Default Title","offer_id":53776346906988,"sku":"PTP200AS0111","price":4257.69,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/PTP200AS0111_Horizontal_Power-Vented_Gas-Fired_Unit_Heater.webp?v=1779282360","url":"https:\/\/cleanflow.net\/products\/ptp300-unit-heater-w-st-steel-heat-exchanger-ng-300-000-btu","provider":"Cleanflow","version":"1.0","type":"link"}