{"product_id":"sje-nex-series-duplex-pump-control-panel-single-phase-120-208-240v-nema-4x-with-alternating-control-alarm","title":"SJE NEX Series Duplex Pump Control Panel – Single Phase, 120\/208\/240V, NEMA 4X with Alternating Control \u0026 Alarm","description":"\u003ch2\u003eCompact UL-Listed Duplex Pump Control Panel With Alternating Control and Override for Residential Sewage and Water Installations\u003c\/h2\u003e\n\n\u003cp\u003eWhen two pumps need to share the load, the SJE NEX Series duplex pump control panel handles it. The compact 10\" x 8\" x 4\" NEMA 4X panel alternates two 120\/208\/240V single-phase pumps to equalize wear, runs override if either pump fails, and triggers an audible\/visual alarm at high level.\u003c\/p\u003e\n\n\u003ch3\u003eQuick Specs\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Duplex (two-pump alternating with override)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 120 \/ 208 \/ 240V single phase, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmperage:\u003c\/strong\u003e 0–12 amps or 9–20 amps (model-dependent)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e 10\" x 8\" x 4\" NEMA 4X UV-stabilized thermoplastic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloat Control Voltage:\u003c\/strong\u003e 12 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Horn:\u003c\/strong\u003e 85–90 dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Alarm Contacts:\u003c\/strong\u003e Form C, 5 amp, 120 VAC max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e UL \/ cUL Listed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 5-Year Limited\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features of the SJE NEX Series Duplex Pump Control Panel\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eAlternating pump control equalizes wear across two pumps, so neither runs as the dedicated lead.\u003c\/li\u003e\n\n\u003cli\u003eOverride control activates the second pump. If either pump fails, the system keeps moving liquid even with a single-pump fault.\u003c\/li\u003e\n\n\u003cli\u003eUniversal 120\/208\/240V single-phase compatibility lets one panel cover three voltage configurations without separate SKUs.\u003c\/li\u003e\n\n\u003cli\u003eNEMA 4X UV-stabilized thermoplastic enclosure withstands moisture, dust, corrosion, and outdoor sun exposure for indoor or outdoor mounting.\u003c\/li\u003e\n\n\u003cli\u003eHOA (Hand-Off-Auto) switches per pump for manual test, bypass, or shutdown when troubleshooting float behavior.\u003c\/li\u003e\n\n\u003cli\u003eStandard alarm package: red 360° beacon, 85–90 dB horn, exterior test\/silence push button auto-resets after high-level condition clears.\u003c\/li\u003e\n\n\u003cli\u003eAuxiliary alarm contacts (Form C, 5A at 120 VAC max) signal external monitoring devices for remote notification.\u003c\/li\u003e\n\n\u003cli\u003eOperates with three or four float switches (Stop, Lead, Lag, Alarm), three-float and four-float package options ship from the factory with 20-ft SJE SignalMaster control switches.\u003c\/li\u003e\n\n\u003cli\u003ePadlockable latch and integral mounting feet keep installation fast, and the enclosure secured against tampering.\u003c\/li\u003e\n\n\u003cli\u003eOptional Elapsed Time Meter (ETM) variants log individual pump run-time in hours for maintenance scheduling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSJE NEX Duplex Pump Control Panel Specifications\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSJE Rhombus\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEX Series®\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDuplex — two-pump alternating with override\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePump Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 \/ 208 \/ 240V single phase, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl \/ Alarm Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 \/ 208 \/ 240V single phase, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePump Amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–12 amps or 9–20 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFloat Control Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFloat Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThree or four floats (Stop, Lead, Lag, Alarm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\" x 8\" x 4\" (25 x 20 x 10 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlockable NEMA 4X, UV-stabilized thermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoor or outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Beacon\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed LED, 360° visual\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Horn\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85–90 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Alarm Contacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eForm C, 5 amp, 120 VAC max\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHOA Switches\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHand-Off-Auto, one per pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicator Lights\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePump run, control\/alarm power, float status\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal-magnetic breaker per pump + control\/alarm fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElapsed Time Meter (ETM) variants\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL \/ cUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePatent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eU.S. Patent No. 10,251,284\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-Year Limited\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePerformance Overview\u003c\/h3\u003e\n\n\u003cp\u003eStop and Lead floats run the lead pump on demand. If the level keeps rising, the Lag float starts the second pump. The Alarm float triggers visual and audible alerts.\u003c\/p\u003e\n\n\u003ch3\u003eConstruction \u0026amp; Internal Components\u003c\/h3\u003e\n\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUV-stabilized thermoplastic, NEMA 4X, hinged door\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegral mounting feet; padlockable latch\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePump Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo thermal-magnetic circuit breakers (one per pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Relays\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo relays — alternate between pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Logic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePCB-based alternator with override on pump fail\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl \/ Alarm Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeparately fused control and alarm circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHOA Switches\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo PCB-mounted Hand-Off-Auto selectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePump run (×2), power, float status, alarm beacon\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLED beacon (360°), 85–90 dB horn, test\/silence button, Form C contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Wiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block; ground lug provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptional\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eElapsed Time Meter — logs run-time per pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eResidential septic systems with two submersible effluent pumps\u003c\/li\u003e\n\u003cli\u003eSewage and effluent pump installations needing redundancy and load balancing\u003c\/li\u003e\n\u003cli\u003eTwo-pump lift stations in low-flow service areas where pump rotation is required\u003c\/li\u003e\n\u003cli\u003eLarger residential or light-commercial sumps with high-volume cycling\u003c\/li\u003e\n\u003cli\u003eReplacement controller for failed direct-wire two-pump installs needing alternation and override\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy Choose the SJE NEX Series Duplex Pump Control Panel?\u003c\/h3\u003e\n\n\u003cp\u003eThe NEX Series duplex panel keeps two residential pumps cycling evenly, with override protection if one pump fails. The layout most installers and inspectors expect on duplex septic and sewage systems.\u003c\/p\u003e\n\n\u003ch4\u003ePairs Well With\u003c\/h4\u003e\n\n\u003cp\u003eSingle-pump installation? Take a look at the \u003ca href=\"https:\/\/cleanflow.net\/products\/sje-nex-series-simplex-pump-control-panel-single-phase-120-208-240v-nema-4x-enclosure-with-alarm-system\"\u003eSJE NEX Series simplex pump control panel\u003c\/a\u003e, same enclosure family and alarm package, sized for a single-pump system.\u003c\/p\u003e\n\n\u003cp\u003eFor high-water alerting on tanks not paired with a pump, browse the \u003ca href=\"https:\/\/cleanflow.net\/collections\/tank-alarm-systems\"\u003etank alarm systems\u003c\/a\u003e collection.\u003c\/p\u003e\n\n\u003ch3\u003eBuy SJE NEX Series Duplex Pump Control Panels Online from Cleanflow\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cleanflow.net\/\"\u003eCleanflow\u003c\/a\u003e\u003c\/strong\u003e stocks the SJE NEX Series duplex pump control panel in panel-only, three-float, and four-float configurations, and ships across Canada and the USA. Add to cart, or contact the Cleanflow team to confirm amperage range and float configuration for your install.\u003c\/p\u003e\n\n\u003cdiv itemscope itemtype=\"https:\/\/schema.org\/FAQPage\"\u003e\n\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eWhat does a duplex pump control panel do?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eA duplex panel runs two pumps from a single controller. It alternates which pump runs first to balance wear, brings in the second pump when the liquid level reaches the lag float, and triggers an alarm if the level keeps rising. If one pump fails, the override puts the working pump on duty.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eHow many float switches does the NEX Series duplex panel use?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eThree or four. A three-float setup uses Stop, Lead\/Lag (combined), and Alarm. A four-float setup uses Stop, Lead, Lag, and Alarm separately. Cleanflow's SKU options ship as panel-only, with three 20-ft SJE SignalMaster floats, or with four 20-ft floats.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eWhat voltages does the NEX Series duplex panel support?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eIt handles 120V, 208V, and 240V single-phase power on the same panel. There is no need to spec a separate model per voltage. Both pump power and control\/alarm power use the same 120\/208\/240V single-phase, 50\/60 Hz feed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eWhat is override control, and when does it activate?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eIf either pump fails to run when called, the panel's override logic activates the working pump to keep liquid moving. The system was designed so that a single pump fault doesn't stop pumping useful for residential sewage, where a flooded basement is the alternative.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eCan the panel be installed outdoors?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eYes. The NEMA 4X UV-stabilized thermoplastic enclosure is rated for indoor or outdoor mounting and resists corrosion, windblown dust, rain, and hose-directed water. Use proper conduit sealing to keep gas and moisture out.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eWhat is the difference between this and the NEX Series simplex panel?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eThe simplex panel runs one pump. The duplex panel runs two pumps with alternating control and override. If you only have one pump, choose simplex; if you have two pumps and need redundancy or load balancing, choose duplex.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eDoes the panel come with an Elapsed Time Meter (ETM)?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003eETM is optional. ETM-equipped variants log individual run-time per pump in hours, which is useful for predictive maintenance and pump-warranty tracking. Standard variants don't include ETMs. Confirm the part number when ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv itemscope itemprop=\"mainEntity\" itemtype=\"https:\/\/schema.org\/Question\"\u003e\n\u003ch4 itemprop=\"name\"\u003eWhat is the warranty?\u003c\/h4\u003e\n\u003cdiv itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\/\/schema.org\/Answer\"\u003e\n\u003cdiv itemprop=\"text\"\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cleanflow.net\/collections\/sje-rhombus\"\u003eSJE Rhombus\u003c\/a\u003e backs the NEX Series duplex panel with a 5-Year Limited Warranty. Warranty is void if the panel is modified. Installation must follow the included instructions and applicable electrical codes (NFPA-70, provincial, and local) by a licensed electrician.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e","brand":"SJE Rhombus","offers":[{"title":"120\/208\/240V Panel \/ 0-12 Amps \/ Panel Only (No Floats)","offer_id":53630707564908,"sku":"1051632","price":1168.72,"currency_code":"CAD","in_stock":true},{"title":"120\/208\/240V Panel \/ 0-12 Amps \/ With (3) 20-Ft Floats","offer_id":53630707597676,"sku":"1051631","price":1306.62,"currency_code":"CAD","in_stock":true},{"title":"120\/208\/240V Panel \/ 0-12 Amps \/ With (4) 20-Ft Floats","offer_id":53630707630444,"sku":"1051630","price":1364.52,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/SJE_NEX_Duplex_Pump_Control_Panel_Single_Phase_Cleanflow.png?v=1778320165","url":"https:\/\/cleanflow.net\/products\/sje-nex-series-duplex-pump-control-panel-single-phase-120-208-240v-nema-4x-with-alternating-control-alarm","provider":"Cleanflow","version":"1.0","type":"link"}