{"product_id":"triple-r-ht113-compact-high-pressure-tester-120v-hydrostatic-test-pump-1000-psi-stainless-ceramic-components","title":"Triple R HT113 Compact High-Pressure Tester – 120V Hydrostatic Test Pump, 1000 PSI, Stainless \u0026 Ceramic Components","description":"\u003ch2 data-start=\"358\" data-end=\"449\"\u003e\u003cstrong data-start=\"361\" data-end=\"449\"\u003eCompact 1000 PSI Hydrostatic Test Pump for Precision, Low-Flow High-Pressure Testing\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"451\" data-end=\"832\"\u003eThe Triple R HT113 Compact High Pressure Tester is engineered for technicians who need precise, controlled hydrostatic testing in a compact, portable format. With an adjustable output range from 50 to 1000 PSI, this unit is ideal for testing valves, lines, fittings, pressure vessels, components, and small systems requiring accurate high-pressure performance verification.\u003c\/p\u003e\n\u003cp data-start=\"834\" data-end=\"1165\"\u003ePowered by a 120V permanent-magnet motor, the HT113 uses a positive displacement pumping mechanism that pressurizes test systems immediately, eliminating lag and providing fast, repeatable test cycles. Its stainless steel check valves prevent backflow and pressure loss, ensuring stable readings throughout the entire test.\u003c\/p\u003e\n\u003cp data-start=\"1167\" data-end=\"1515\"\u003eBuilt from aircraft-grade aluminum with an AL203 hardcoat anodized finish, and equipped with stainless steel valves, Buna seals, and a ceramic plunger, this pump is designed for true commercial-grade durability. The unit also features a glycerin-filled 2000 PSI gauge for vibration resistance and accurate monitoring during testing.\u003c\/p\u003e\n\u003cp data-start=\"1517\" data-end=\"1696\"\u003eDespite its rugged construction, the HT113 weighs only 15 lbs and measures 5.69\"W × 3.79\"H × 8.2\"L, making it one of the most portable hydrostatic test pumps in its class.\u003c\/p\u003e\n\u003cp data-start=\"1698\" data-end=\"1840\"\u003eIdeal for plumbing contractors, industrial maintenance teams, fire protection technicians, OEM testing lines, and field service professionals.\u003c\/p\u003e\n\u003chr data-start=\"1842\" data-end=\"1845\"\u003e\n\u003ch2 data-start=\"1847\" data-end=\"1925\"\u003e\u003cstrong data-start=\"1850\" data-end=\"1925\"\u003eFeatures of the Triple R HT113 Compact High-Pressure Hydrostatic Tester\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1927\" data-end=\"2646\"\u003e\n\u003cli data-start=\"1927\" data-end=\"1978\"\u003e\n\u003cp data-start=\"1929\" data-end=\"1978\"\u003eAdjustable output pressure from 50–1000 PSI\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1979\" data-end=\"2045\"\u003e\n\u003cp data-start=\"1981\" data-end=\"2045\"\u003eFast, stable pressurization via positive displacement pump\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2046\" data-end=\"2129\"\u003e\n\u003cp data-start=\"2048\" data-end=\"2129\"\u003eAircraft-grade aluminum body with hardcoat anodizing for extreme durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2130\" data-end=\"2192\"\u003e\n\u003cp data-start=\"2132\" data-end=\"2192\"\u003eStainless steel check valves ensure zero pressure loss\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2193\" data-end=\"2262\"\u003e\n\u003cp data-start=\"2195\" data-end=\"2262\"\u003eCeramic plunger for long service life and chemical resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2263\" data-end=\"2360\"\u003e\n\u003cp data-start=\"2265\" data-end=\"2360\"\u003eBuna seals for dependable sealing and compatibility with clean water and many test fluids\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2361\" data-end=\"2429\"\u003e\n\u003cp data-start=\"2363\" data-end=\"2429\"\u003eGlycerin-filled 2000 PSI gauge for steady, accurate readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2430\" data-end=\"2480\"\u003e\n\u003cp data-start=\"2432\" data-end=\"2480\"\u003eLightweight, portable design — only 15 lbs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2481\" data-end=\"2534\"\u003e\n\u003cp data-start=\"2483\" data-end=\"2534\"\u003eOperates on 120VAC, drawing just 1.5 amps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2535\" data-end=\"2609\"\u003e\n\u003cp data-start=\"2537\" data-end=\"2609\"\u003eTwin ¼\" FNPT inlet and discharge ports for flexible plumbing setup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2610\" data-end=\"2646\"\u003e\n\u003cp data-start=\"2612\" data-end=\"2646\"\u003eRated for fluids up to 140°F\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2648\" data-end=\"2651\"\u003e\n\u003ch2 data-start=\"2653\" data-end=\"2674\"\u003e\u003cstrong data-start=\"2656\" data-end=\"2674\"\u003eSpecifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2676\" data-end=\"3208\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2676\" data-end=\"2699\"\u003e\n\u003ctr data-start=\"2676\" data-end=\"2699\"\u003e\n\u003cth data-start=\"2676\" data-end=\"2688\" data-col-size=\"sm\"\u003eComponent\u003c\/th\u003e\n\u003cth data-start=\"2688\" data-end=\"2699\" data-col-size=\"sm\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2723\" data-end=\"3208\"\u003e\n\u003ctr data-start=\"2723\" data-end=\"2753\"\u003e\n\u003ctd data-start=\"2723\" data-end=\"2735\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2725\" data-end=\"2734\"\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2735\" data-end=\"2753\"\u003eTriple R HT113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2754\" data-end=\"2785\"\u003e\n\u003ctd data-start=\"2754\" data-end=\"2773\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2756\" data-end=\"2772\"\u003eMax Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2773\" data-end=\"2785\"\u003e1000 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2786\" data-end=\"2814\"\u003e\n\u003ctd data-start=\"2786\" data-end=\"2802\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2788\" data-end=\"2801\"\u003eOpen Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2802\" data-end=\"2814\"\u003e0.25 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2815\" data-end=\"2839\"\u003e\n\u003ctd data-start=\"2815\" data-end=\"2829\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2817\" data-end=\"2828\"\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2829\" data-end=\"2839\"\u003e120VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2840\" data-end=\"2864\"\u003e\n\u003ctd data-start=\"2840\" data-end=\"2855\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2842\" data-end=\"2854\"\u003eAmperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2855\" data-end=\"2864\" data-col-size=\"sm\"\u003e1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2865\" data-end=\"2903\"\u003e\n\u003ctd data-start=\"2865\" data-end=\"2876\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2867\" data-end=\"2875\"\u003eBody\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2876\" data-end=\"2903\"\u003eAircraft-Grade Aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2904\" data-end=\"2929\"\u003e\n\u003ctd data-start=\"2904\" data-end=\"2918\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2906\" data-end=\"2917\"\u003ePlunger\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2918\" data-end=\"2929\"\u003eCeramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2930\" data-end=\"2962\"\u003e\n\u003ctd data-start=\"2930\" data-end=\"2943\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2932\" data-end=\"2942\"\u003eValves\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2943\" data-end=\"2962\" data-col-size=\"sm\"\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2963\" data-end=\"2983\"\u003e\n\u003ctd data-start=\"2963\" data-end=\"2975\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2965\" data-end=\"2974\"\u003eSeals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2975\" data-end=\"2983\"\u003eBuna\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2984\" data-end=\"3025\"\u003e\n\u003ctd data-start=\"2984\" data-end=\"2996\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2986\" data-end=\"2995\"\u003eGauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2996\" data-end=\"3025\" data-col-size=\"sm\"\u003eGlycerin-Filled, 2000 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3026\" data-end=\"3049\"\u003e\n\u003ctd data-start=\"3026\" data-end=\"3039\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3028\" data-end=\"3038\"\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3039\" data-end=\"3049\"\u003e15 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3050\" data-end=\"3094\"\u003e\n\u003ctd data-start=\"3050\" data-end=\"3067\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3052\" data-end=\"3066\"\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3067\" data-end=\"3094\"\u003e5.69\"W × 3.79\"H × 8.2\"L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3095\" data-end=\"3130\"\u003e\n\u003ctd data-start=\"3095\" data-end=\"3113\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3097\" data-end=\"3112\"\u003eInlet Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3113\" data-end=\"3130\"\u003e(2) × ¼\" FNPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3131\" data-end=\"3170\"\u003e\n\u003ctd data-start=\"3131\" data-end=\"3153\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3133\" data-end=\"3152\"\u003eDischarge Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3153\" data-end=\"3170\"\u003e(2) × ¼\" FNPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3171\" data-end=\"3208\"\u003e\n\u003ctd data-start=\"3171\" data-end=\"3199\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"3173\" data-end=\"3198\"\u003eMax Fluid Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"3199\" data-end=\"3208\"\u003e140°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/113C_Compact_Pumptec_Pump_Flow_Chart.jpg?v=1769186732\" alt=\"PMDC Performance Chart\" style=\"margin-right: 24.5px; margin-left: 24.5px; float: none;\"\u003e\u003c\/div\u003e\n\u003chr data-start=\"3210\" data-end=\"3213\"\u003e\n\u003ch2 data-start=\"3215\" data-end=\"3255\"\u003e\u003cstrong data-start=\"3218\" data-end=\"3255\"\u003eFrequently Asked Questions (FAQs)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"3257\" data-end=\"3303\"\u003e\u003cstrong data-start=\"3261\" data-end=\"3301\"\u003eWhat is the Triple R HT113 used for?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3304\" data-end=\"3485\"\u003eIt is designed for low-flow, high-pressure hydrostatic testing of valves, fittings, piping, coils, heat exchangers, and other pressurizable systems requiring up to 1000 PSI.\u003c\/p\u003e\n\u003ch3 data-start=\"3487\" data-end=\"3519\"\u003e\u003cstrong data-start=\"3491\" data-end=\"3517\"\u003eIs this pump portable?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3520\" data-end=\"3638\"\u003eYes. At only \u003cstrong data-start=\"3533\" data-end=\"3543\"\u003e15 lbs\u003c\/strong\u003e and less than 9 inches long, it is extremely portable and ideal for field service technicians.\u003c\/p\u003e\n\u003ch3 data-start=\"3640\" data-end=\"3679\"\u003e\u003cstrong data-start=\"3644\" data-end=\"3677\"\u003eWhat makes this unit durable?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3680\" data-end=\"3697\"\u003eThe HT113 uses:\u003c\/p\u003e\n\u003cul data-start=\"3698\" data-end=\"3849\"\u003e\n\u003cli data-start=\"3698\" data-end=\"3734\"\u003e\n\u003cp data-start=\"3700\" data-end=\"3734\"\u003e\u003cstrong data-start=\"3700\" data-end=\"3732\"\u003eAircraft-grade aluminum body\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3735\" data-end=\"3769\"\u003e\n\u003cp data-start=\"3737\" data-end=\"3769\"\u003e\u003cstrong data-start=\"3737\" data-end=\"3767\"\u003eAL203 hardcoat anodization\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3770\" data-end=\"3806\"\u003e\n\u003cp data-start=\"3772\" data-end=\"3806\"\u003e\u003cstrong data-start=\"3772\" data-end=\"3804\"\u003eStainless steel check valves\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3807\" data-end=\"3830\"\u003e\n\u003cp data-start=\"3809\" data-end=\"3830\"\u003e\u003cstrong data-start=\"3809\" data-end=\"3828\"\u003eCeramic plunger\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3831\" data-end=\"3849\"\u003e\n\u003cp data-start=\"3833\" data-end=\"3849\"\u003e\u003cstrong data-start=\"3833\" data-end=\"3847\"\u003eBuna seals\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3851\" data-end=\"3929\"\u003eThese materials provide exceptional wear resistance and long-term performance.\u003c\/p\u003e\n\u003ch3 data-start=\"3931\" data-end=\"3984\"\u003e\u003cstrong data-start=\"3935\" data-end=\"3982\"\u003eDoes the pump lose pressure during testing?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3985\" data-end=\"4096\"\u003eNo. The stainless steel check valves prevent pressure loss, allowing stable hydrostatic readings over time.\u003c\/p\u003e\n\u003ch3 data-start=\"4098\" data-end=\"4144\"\u003e\u003cstrong data-start=\"4102\" data-end=\"4142\"\u003eWhat fluid can be used in this pump?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4145\" data-end=\"4235\"\u003eIt is intended for clean water and compatible test fluids at temperatures up to 140°F.\u003c\/p\u003e\n\u003ch3 data-start=\"4237\" data-end=\"4277\"\u003e\u003cstrong data-start=\"4241\" data-end=\"4275\"\u003eWhat is the power requirement?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4278\" data-end=\"4372\"\u003eThe pump runs on 120V AC and draws 1.5 amps, making it ideal for shop and jobsite use.\u003c\/p\u003e\n\u003ch3 data-start=\"4374\" data-end=\"4418\"\u003e\u003cstrong data-start=\"4378\" data-end=\"4416\"\u003eWhat size connections does it use?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4419\" data-end=\"4538\"\u003eThe pump features two ¼\" FNPT inlets and two ¼\" FNPT discharge ports, offering flexibility for your test setup.\u003c\/p\u003e\n\u003ch3 data-start=\"4540\" data-end=\"4577\"\u003e\u003cstrong data-start=\"4544\" data-end=\"4575\"\u003eIs the pressure adjustable?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4578\" data-end=\"4656\"\u003eYes. The output pressure can be adjusted anywhere between 50 and 1000 PSI.\u003c\/p\u003e\n\u003ch3 data-start=\"4658\" data-end=\"4704\"\u003e\u003cstrong data-start=\"4662\" data-end=\"4702\"\u003eDoes it come with hoses or fittings?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"4705\" data-end=\"4828\"\u003eThis listing is for the pump unit only. Hoses and fittings should be purchased separately based on your test configuration.\u003c\/p\u003e","brand":"Triple R","offers":[{"title":"Default Title","offer_id":53104337125740,"sku":"82016","price":1158.22,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1016\/5405\/files\/113C-Hydrostatic-test-Pump-resized.jpg?v=1769186672","url":"https:\/\/cleanflow.net\/products\/triple-r-ht113-compact-high-pressure-tester-120v-hydrostatic-test-pump-1000-psi-stainless-ceramic-components","provider":"Cleanflow","version":"1.0","type":"link"}