Milwaukee MW401 PRO Low Range Portable Total Dissolved Solids (TDS) Meter


Price:
Sale price$387.44 CAD
Free shipping
Stock:
In stock
Brand-Wide Volume Discounts: More Items, More Savings!

Pickup available at Cleanflow Winnipeg Warehouse

Usually ready in 24 hours

This item is normally regularly stocked. Shipping times may vary depending on availability. Please contact us to confirm stock and shipping times. You will receive tracking details once the item has shipped.

Description

Milwaukee MW401 PRO Low Range Total Dissolved Solids (TDS) Meter

The Milwaukee MW401 PRO Total Dissolved Solids (TDS) Meter is a reliable, portable instrument designed for fast and accurate measurement of total dissolved solids (TDS) in water. Featuring automatic temperature compensation (ATC), a professional SE510 conductivity probe, and an easy-to-read LCD display, the MW401 is ideal for laboratories, aquariums, aquaculture, water treatment, food processing, and water conditioning applications.

Accurate measurement of dissolved solids helps improve water quality, optimize treatment processes, and reduce operating costs. Whether monitoring drinking water, nutrient solutions, aquariums, or industrial water systems, the MW401 delivers dependable readings in a lightweight, easy-to-use design suitable for both professionals and hobbyists.

Supplied complete with the SE510 conductivity probe, a 1382 ppm calibration solution, and a long-life battery, the Milwaukee MW401 is ready for immediate use.


Why Measure Total Dissolved Solids?

Total Dissolved Solids (TDS) represent the concentration of dissolved minerals, salts, and other substances present in water. Monitoring TDS helps maintain water quality and improve system performance across many applications.

Common benefits include:

  • Monitoring drinking water quality
  • Optimizing water treatment systems
  • Managing nutrient concentrations
  • Improving aquarium and aquaculture health
  • Supporting laboratory testing
  • Reducing chemical consumption
  • Maintaining process consistency

Product Specifications

Specification Details
Manufacturer Milwaukee Instruments
Model MW401 PRO
Product Type Portable Total Dissolved Solids (TDS) Meter
Measurement Range 0–1990 mg/L (ppm)
Resolution 1 mg/L (ppm)
Accuracy ±2% Full Scale @ 25°C
TDS Conversion Factor 0.50
Temperature Compensation Automatic (5–50°C / 41–122°F)
Included Probe SE510 Conductivity Probe
Probe Cable Length 1 m (3.3 ft)
Calibration Solution Included MI0032B 1382 ppm Standard
Battery 1 × 9V Alkaline
Battery Life Approximately 300 Hours
Operating Temperature 0–50°C (32–122°F)
Meter Dimensions 143 × 80 × 32 mm
Meter Weight 0.23 kg (0.5 lb)

Features & Benefits

Accurate Low Range TDS Measurement

Measures dissolved solids from 0 to 1990 mg/L (ppm) with 1 ppm resolution, making it suitable for a wide variety of water quality applications.

Automatic Temperature Compensation (ATC)

Automatically compensates measurements for water temperature to improve testing accuracy.

Professional Conductivity Probe Included

Supplied with the Milwaukee SE510 conductivity probe featuring a 3.3-foot cable for convenient sampling.

Large LCD Display

Easy-to-read digital display provides clear measurement values for both field and laboratory work.

Portable & Lightweight

Compact design makes the MW401 easy to carry between sampling locations while remaining durable for everyday use.

Long Battery Life

Operates for approximately 300 hours on a single 9V alkaline battery.

Ready to Use

Includes a 1382 ppm calibration solution so users can calibrate the instrument before testing.


Ideal Applications

The Milwaukee MW401 PRO is ideal for:

  • Drinking water testing
  • Water treatment plants
  • Water conditioning systems
  • Reverse osmosis systems
  • Aquariums
  • Aquaculture
  • Hydroponics
  • Food processing
  • Beverage production
  • Environmental monitoring
  • Research laboratories
  • Educational institutions

Why Monitor TDS?

Improve Water Quality

Routine TDS testing helps identify changes in water quality before they become larger problems.

Optimize Water Treatment

Monitoring dissolved solids allows operators to improve filtration efficiency and reduce treatment costs.

Support Healthy Aquatic Systems

Maintaining proper TDS levels promotes healthier conditions for fish, aquatic plants, and other aquatic life.

Verify Drinking Water Quality

TDS measurements help evaluate the effectiveness of filtration and water conditioning systems.


Calibration & Maintenance

For best performance:

  • Calibrate regularly using 1382 ppm calibration solution (MI0032B or MA9062).
  • Rinse the probe with clean water after each use.
  • Store the probe clean and protected when not in use.
  • Replace calibration solution regularly to maintain measurement accuracy.

Routine calibration ensures the meter continues to provide accurate and repeatable TDS measurements.


Frequently Asked Questions

What does the MW401 measure?

The MW401 measures Total Dissolved Solids (TDS) in water.

What is the measurement range?

The meter measures from 0 to 1990 mg/L (ppm).

What accuracy does the MW401 provide?

The instrument provides ±2% Full Scale accuracy at 25°C.

Does the meter automatically compensate for temperature?

Yes. The MW401 features Automatic Temperature Compensation (ATC) from 5°C to 50°C.

Is a probe included?

Yes. The meter includes the Milwaukee SE510 conductivity probe with a 1 metre (3.3 ft) cable.

Is calibration solution included?

Yes. The MW401 includes MI0032B 1382 ppm calibration solution for initial calibration.

How long does the battery last?

The meter operates for approximately 300 hours using one 9V alkaline battery.

Who is this meter designed for?

The MW401 is suitable for water treatment professionals, laboratories, aquaculture operations, aquarium owners, hydroponic growers, food processing facilities, and anyone monitoring water quality.

Similar Products

Featured collection