Parts and Accessories from Lovibond

Lovibond offers a comprehensive selection of high-quality cuvettes designed to support accurate and reliable water analysis in laboratory settings. Available in various materials such as optical glass, borosilicate, and quartz, these cuvettes accommodate a wide range of path lengths and applications—from photometric to turbidity measurements. Specialized options, including round sample cells with black lids for turbidimeters, are engineered to minimize light interference and enhance measurement precision. Each cuvette is manufactured to meet strict international standards, ensuring compatibility with Lovibond instruments and consistent performance. Designed for ease of use, proper fit, and optical clarity, Lovibond cuvettes are essential tools for achieving dependable, reproducible test results in water quality testing.

Why Choose Lovibond Parts and Accessories?

Lovibond parts and accessories are designed to ensure optimal performance, accuracy, and longevity of water testing instruments. From precision-engineered cuvettes to essential replacement components, each item supports seamless integration and reliability in analytical and scientific environments. Trusted by laboratories and industries worldwide, Lovibond accessories enhance test consistency, minimize contamination risks, and help maintain the integrity of critical measurements. Explore these parts and accessories at our Canadian warehouse, or check them out below:

  • Lovibond Glass Sample Cuvettes

    • Lovibond Glass Sample Cuvettes are high-quality, precision-engineered glass containers designed specifically for use with Lovibond MD 100 and MD 600 colorimeters. Made from premium 24mm glass and holding 10 ml of sample volume, they ensure accurate, consistent water testing results. Ideal for various applications, these cuvettes are available in convenient packs of 5 or 12, making them a reliable choice for laboratories and professionals seeking dependable water analysis.

  • Lovibond 197655 Portable Turbidimeter Sample Cuvettes

    • The Lovibond 197655 Portable Turbidimeter Sample Cuvettes are a set of twelve high-quality sample cells with caps, specifically designed for use with Lovibond TB 210 IR, TB 211 IR, TB 300 IR, and TB350 Portable Turbidimeters. These cuvettes support accurate and efficient turbidity measurements and require proper storage to maintain performance.

  • Lovibond Sample Cell Cleaning Cloth

    • The Lovibond Sample Cell Cleaning Cloth is a dual-purpose tool designed for precision cleaning of sample cells and cuvettes, as well as for applying silicone oil to turbidimeter sample cells. It ensures even oil distribution for accurate water analysis results and supports optimal instrument performance. Easy to use, it involves applying, spreading, and wiping off excess oil for a thin, uniform coat.

FAQs

1. Why is it important to use the correct cuvette size for Lovibond colorimeters and turbidimeters?

Using the correct cuvette size, like the 24mm cuvettes for MD 100 and MD 600 or the 197655 sample cells for TB series turbidimeters, ensures accurate path length alignment and compatibility with the optical system. A mismatch can lead to erroneous readings, contamination risk, or even physical damage to sensitive instruments over time.

2. How does the Lovibond Sample Cell Cleaning Cloth improve the performance of cuvettes and instruments?

This specially designed cloth offers dual functionality: it thoroughly cleans cuvettes to remove residue and also allows for uniform application of silicone oil on turbidimeter cuvettes. This uniform coating prevents light scattering, enhances optical clarity, and ensures consistent and reliable turbidity readings in field or lab settings.

3. Can improper storage of cuvettes affect test accuracy, and how should Lovibond cuvettes be stored?

Yes, improper storage can lead to contamination, scratches, or residue build-up, which can distort optical readings. Lovibond recommends storing cuvettes filled with deionized or distilled water, with caps on, and wiping the exterior dry before storage. This preserves the integrity of the glass and ensures cuvettes are always ready for accurate testing.

4. How often should I replace Lovibond cuvettes or accessories for optimal performance?

Replacement depends on usage frequency and care. However, regular visual inspections can help detect scratches, residue, or discoloration. If cuvettes show signs of wear or cause inconsistent results even after cleaning, it’s time to replace them. Using fresh, undamaged accessories ensures test accuracy and protects your instrumentation.

5. How do Lovibond accessories support quality control in laboratory and field testing?

Lovibond accessories, from precision glass cuvettes to reliable cleaning tools, uphold strict measurement standards by ensuring consistent sample handling and cleanliness. Their use reduces variables that can distort results, enabling dependable readings in both controlled lab environments and unpredictable field conditions.