ADEY Inhibitor Test Strips – Quick & Precise Inhibitor Measurement for Hydronic Heating System

SKU: CH3-03-06189

Price:
Sale price$105.45 CAD
Free shipping
Stock:
In stock
Brand-Wide Volume Discounts: More Items, More Savings!

This item is normally regularly stocked. Shipping times may vary depending on availability. Please contact us to confirm stock and shipping times. You will receive tracking details once the item has shipped.

Description

Fast and Accurate Inhibitor Concentration Testing No Setup Required Test Inhibitor Strips

The ADEY Inhibitor Test Strips delivers fast and accurate testing of inhibitor concentration in hydronic heating systems. This hydronic heating inhibitor test strip reads inhibitor levels directly from a small water sample, providing a clear color-coded result in a matter of seconds with no laboratory, no calibration, and no initial set-up required. Available in airtight waterproof containers and manufactured under ISO 9001 quality standards.

For On-Site Hydronic Inhibitor Level Verification

The ADEY Quick Test Inhibitor Strip is a cost-effective alternative to other inhibitor testing solutions on the market. It provides onsite testing with no initial set-up requirements, making it practical for use across multiple job sites in a single day without carrying additional equipment.

This makes it an essential tool for every boiler service call, post-flush system recommission, and routine water quality check. If you are looking to buy ADEY inhibitor test strips, each 50-strip canister covers 50 individual service visits at one test per call.

Key Features of ADEY Inhibitor Test Strips

  • Fast & Accurate Corrosion Detection: Quickly identify the presence of corrosion in your heating systems.
  • Ease of Use: Simple, straightforward application for immediate results.
  • Onsite Testing Capability: No need for initial setup, ideal for use in various locations.
  • Swift Results: Get corrosion level readings within seconds.
  • Economical Choice: An affordable alternative to more expensive testing methods.
  • Secure Packaging: Comes in airtight, waterproof canisters, ensuring strip integrity.
  • Quantity: Each canister contains 50 test strips, with master packs of 18 canisters.

Specifications

Specification Details
Product Name ADEY Quick Test Inhibitor Strip
Product Use Fast and accurate testing of inhibitor concentration in hydronic heating systems
Dip Time 1 second
Result Time 10 seconds (results in a matter of seconds)
Strips Per Canister 50
Canister Type Airtight, waterproof plastic container
Physical Appearance Plastic strip, white
Odour N/A
Classification Non-hazardous, non-toxic
Quality Standard ISO 9001
Environmental Status ADEY is a carbon neutral company
Storage Cool, well-ventilated area

Why Choose ADEY Quick Test Inhibitor Strips

These inhibitor test strips give contractors and building owners fast, reliable on-site confirmation that inhibitor concentration in the system water is adequate, without the cost or delay of laboratory testing.

  • Easy to use: No technical expertise, no equipment, and no initial set-up required
  • Fast and accurate testing: Results in a matter of seconds directly from a small water sample
  • Onsite testing capability: Suitable for use across multiple locations in a single day
  • Cost-effective alternative: Professional-grade inhibitor concentration testing at low cost per test
  • Airtight waterproof container: Preserves strip accuracy from first use through the last strip in the canister
  • 50 strips per canister: High test count for contractors on busy service routes
  • ISO 9001 quality manufacturing: Consistent, reliable performance across every canister

These features eliminate guesswork about system inhibitor status and support a documented, repeatable water quality check at every hydronic heating service call.

Applications

The ADEY Quick Test Inhibitor Strip is used across a wide range of hydronic heating maintenance scenarios:

  • Annual boiler service visits to verify inhibitor concentration before the heating season
  • Post-flush system recommissioning to confirm inhibitor levels after cleaning
  • After any full or partial system drain-down that may have diluted inhibitor concentration
  • New system commissioning to verify that inhibitor was correctly dosed at startup
  • Radiant floor heating systems where regular inhibitor top-up is part of the maintenance plan
  • Light commercial hydronic systems requiring routine water quality monitoring
  • Retrofit projects where the existing inhibitor type and concentration are unknown

Its simple dip-and-read method and no-setup design make it suitable for residential service calls and commercial building maintenance programs alike.

How to Use ADEY Quick Test Inhibitor Strips

The Quick Test Inhibitor Strip by Adey requires only a small water sample from the system. The five-step process is the same at any job site with no equipment or preparation needed.

  • Step 1: Drain a small sample of system water from the system.
  • Step 2: Dip the strip in water for 1 second.
  • Step 3: Shake off excess liquid.
  • Step 4: Leave for 10 seconds as the water soaks into the pad.
  • Step 5: After 10 seconds compare the result with the color scale on the side of the canister to indicate inhibitor concentration level.

Record the result, system address, and test date in your service documentation. If the result indicates a low or absent inhibitor, top up with the ADEY MC1+ inhibitor and retest after allowing the inhibitor to fully circulate through the system.

Get ADEY Quick Test Inhibitor Strips Today

The ADEY Quick Test Inhibitor Strip from Cleanflow delivers fast and accurate inhibitor concentration testing in a convenient 50-strip airtight canister. Easy to use, results in seconds, and a cost-effective alternative to other solutions on the market; it belongs in every hydronic heating contractor's service bag.

Buy ADEY inhibitor test strips today and add a fast, accurate inhibitor check to every hydronic heating service call.

What does the ADEY Quick Test Inhibitor Strip measure?

The ADEY Quick Test Inhibitor Strip delivers fast and accurate testing of inhibitor concentration in hydronic heating systems. It indicates whether the inhibitor level in the system water is adequate to protect against corrosion and scale.

How long does the test take?

Dip the strip in the water sample for 1 second, shake off excess liquid, and leave for 10 seconds as the water soaks into the pad. After 10 seconds, compare the result with the color scale on the side of the canister. The full process takes well under a minute.

Do I need any tools or equipment to run the test?

No tools or equipment are required. The strip provides onsite testing with no initial set-up requirements. Drain a small sample of system water, dip, shake, wait 10 seconds, and read the color scale. No calibration, reagent preparation, or measuring equipment needed.

How many strips come in each canister?

Each canister contains 50 test strips stored in an airtight waterproof container that preserves strip accuracy between uses. ADEY also supplies master packs of 18 canisters for bulk purchasing.

Is the ADEY inhibitor strip cost effective compared to other testing methods?

Yes. The ADEY Quick Test Inhibitor Strip is a cost-effective alternative to other solutions on the market. It delivers professional inhibitor concentration results at a low cost per test, without the expense of laboratory water analysis or specialist electronic testing equipment.

What should I do if the result shows a low or absent inhibitor?

If the strip indicates that inhibitor concentration is below the required level, top up the system with an ADEY MC1+ inhibitor according to the system volume. Allow time for the inhibitor to fully circulate through the system, then retest with a fresh strip to confirm that adequate protection has been restored.

Are the strips safe to handle?

ADEY Quick Tests are classified as non-hazardous and non-toxic. Keep out of reach of children. Avoid contact with eyes and skin. In case of contact with eyes, bathe the eye with running water for 15 minutes. In case of contact with skin, wash with plenty of soap and water. Store in a cool, well-ventilated area. Dispose of in accordance with local regulations.

What other ADEY water tests work alongside the inhibitor strip?

ADEY offers three on-site water test strips as part of its Best Practice water testing suite. The inhibitor strip confirms inhibitor concentration. The ADEY Quick Test Corrosion Strip identifies whether corrosion has built up or is building in the system. The ADEY pH Quick Test Strip checks system water acidity and alkalinity levels. All three tests together provide a complete water chemistry assessment onsite.

How should the strips be stored?

Store in the original airtight waterproof container in a cool, well-ventilated area. Keep out of reach of children. Do not expose to excessive humidity or moisture between uses, as this can affect strip reagent accuracy.