Categories
- Shop All (4177)
-
- Automotive Equipment (63)
- Drain Line Cleaning Equipment (45)
- Drain Line De-Icing Equipment (29)
- Facility Equipment (27)
- Heaters (68)
- Pipe Inspection & Locators (29)
- Top Equipment Brands (155)
- Pressure Washers (49)
- Safety Equipment (24)
- Shop Equipment (43)
- Water Testing Equipment (62)
- Yard Equipment (52)


Well Pressure Tanks and Installation Kits
22 products
Showing 1 - 22 of 22 products




















What Are Pressure Tanks?
Pressure tanks are essential in water systems, storing water and regulating flow to maintain steady pressure. They work with well pumps or municipal supplies to reduce pump cycling, ensuring consistent water pressure. Benefits include improved water flow stability, extended pump lifespan by minimizing frequent cycling, and enhanced energy efficiency through optimized pump operation. Cleanflow stocks the well pressure tank itself, from 14 to 119 gallons, plus the tank tees, switches, relief valves and installation kits needed for a new system or a pressure tank replacement. For pumps to pair with them, see well pumps and pressure tanks.
Types of Pressure Tanks
1. Well Pressure Tanks:
Used in well systems to store water and maintain pressure.
-
Common types include:
Diaphragm Tanks: Feature a diaphragm separating air and water. The Flexcon Well-Rite range (20 to 119 gallons) and the Red Lion RL14A are diaphragm tanks; the membrane is fixed to the tank wall and is not serviceable, so a failed diaphragm means a new tank.
Bladder Tanks: Utilize a replaceable bladder to hold water. WellMate composite tanks use a replaceable air cell; Cleanflow stocks the WellMate air cell replacement kit for them.
Air-Over-Water Tanks: Mix air and water but require periodic air replenishment. Older galvanized tanks work this way and waterlog over time. A pre-charged diaphragm tank of the same volume replaces one directly.
How to Choose a Well Pressure Tank
Size a well pressure tank by drawdown, not total volume. Drawdown is the water the tank delivers between pump starts, about 25 to 30 percent of the tank's volume. Plan 1 gallon of drawdown per GPM of pump output: a 10 GPM pump pairs with a 33 to 44 gallon tank. Match the connection to your tank tee, 1 in. NPT on the smaller Well-Rite tanks and 1-1/4 in. NPT from 44 gallons up.
| Tank | Volume | Connection | Typical fit |
|---|---|---|---|
| Red Lion RL14A | 14 gal, 150 PSI | 1 in. FNPT | Cottages, up to four fixtures, pumps to 6 GPM |
| Flexcon Well-Rite WR-60R | 20 gal, 125 PSI | 1 in. NPT | Small homes, 7 to 10 GPM pumps |
| Flexcon Well-Rite WR-80R / WR-120R | 26 / 33.4 gal, 125 PSI | 1 in. NPT | Three-bedroom homes, 10 GPM pumps |
| Flexcon Well-Rite WR-140R / WR-200R | 44 / 62 gal, 125 PSI | 1-1/4 in. NPT | Larger households, 10 to 15 GPM pumps |
| Flexcon Well-Rite WR-240R / WR-260R / WR-360R | 81 / 85 / 119 gal, 125 PSI | 1-1/4 in. NPT | Farms, acreages, irrigation and commercial systems |
| Flexcon Jet-Rite PJR-6 / PJR15 / PJR25 | 2.1 / 4.8 / 9 gal inline | 3/4 in. NPT | Jet pumps and booster pumps |
All Well-Rite tanks are NSF/ANSI 61 listed for potable water. Browse the full Flexcon range, or read fiberglass vs steel pressure tank if your water is corrosive.
Replacing a Well Pressure Tank
A well pressure tank replacement is a same-day job on an existing system when three things match: the volume, the connection size, and the tank tee. The 304 stainless steel installation kit bundles the union tank tee, 30/50 PSI switch, 75 PSI relief valve, gauge and hose bib, so the new tank connects without hunting for fittings. If the old tee is sound, a union tank tee on its own is enough. Before the water goes back on, set the air pre-charge 2 PSI below the switch cut-in: 28 PSI for a 30/50 switch. Not sure the tank has failed? The post signs your well pressure tank is bad covers the checks.
Explore Pressure Tanks & Installation Kits at Our Canadian Warehouse
-
Flexcon Well-Rite WR-60R 20 Gallon Pre-Charged Pressure Tank
The Flexcon Well-Rite WR-60R 20 Gallon Pre-Charged Pressure Tank is a 20-gallon pre-charged diaphragm pressure tank designed for residential and commercial well water systems. Built with a 16-gauge steel body and a urethane paint finish, it offers excellent corrosion resistance. Its internal butyl rubber diaphragm and anti-microbial copolymer propylene lower chamber enhance durability and hygiene while preventing condensation and chafing. The tank is pre-charged to 38 PSI (adjustable) for easy installation and supports various pressure switch settings with efficient water drawdown. The same Well-Rite construction runs through the WR-80R (26 gal), WR-120R (33.4 gal), WR-140R (44 gal), WR-200R (62 gal), WR-240R (81 gal), WR-260R (85 gal) and WR-360R (119 gal).
-
Red Lion RL14A Pre-Charged 14 Gallon Pressure Tank
The Red Lion RL14A Pre-Charged 14 Gallon Pressure Tank enhances residential water systems by maintaining consistent pressure and reducing pump cycling. Designed for homes with up to four water fixtures and pump outputs up to 6 GPM, it features a heavy-duty 20-gauge steel body, a Leak Safe polypropylene liner, and a high-efficiency Butyl Rubber diaphragm. NSF-certified for clean water assurance, it supports various well pump types and offers flexible installation options.
-
304 Stainless Steel Pressure Tank Installation Kit
The 304 Stainless Steel Pressure Tank Installation Kit offers a durable, corrosion-resistant, and cost-effective plumbing solution for residential and commercial water systems. Made from high-quality 304 stainless steel, the kit's union tank tee, 30/50 PSI switch, 75 PSI relief valve, gauge and hose bib ensure long-lasting performance, compliance with No-Lead regulations, and compatibility with various pressure tanks. The built-in union simplifies tank replacement, reducing labor and maintenance time. A lead-free brass version of the kit, a Boshart stainless manifold kit, and the WellMate quick-connect kit are also available from Cleanflow.
FAQs
How does the Flexcon Well-Rite prevent condensation buildup?
The Flexcon Well-Rite is designed with an anti-microbial copolymer polypropylene lower chamber, which not only resists bacterial growth but also minimizes condensation inside the tank. This feature prevents water accumulation on the exterior, reducing the risk of corrosion and prolonging the tank’s lifespan.
Can I adjust the pre-charge pressure of the Flexcon Well-Rite, and how do I do it?
Yes, the Flexcon Well-Rite comes pre-charged at 38 PSI but can be adjusted to match your specific pressure switch settings. To adjust, simply turn off the pump, drain the system, and use a tire pressure gauge to check the air pressure at the Schrader valve on top. Use an air compressor to add or release air as needed, ensuring it’s set 2 PSI below the pump cut-in pressure.
What makes the Red Lion ideal for small households?
With a 14-gallon capacity, the Red Lion is designed for homes with up to four water fixtures and supports pumps with up to 6 GPM output. Its heavy-duty steel body, Leak Safe polypropylene liner, and efficient diaphragm ensure reliable performance and reduced pump cycling.
How do I know when a well pressure tank needs replacement?
Short cycling (the pump starting every few seconds), water at the air valve, or a tank that will not hold its pre-charge after you drain it and recharge it all mean the diaphragm has failed. The tank is replaced, not repaired. A tank that only lost air and holds the new charge is fine.
What is the difference between a bladder tank and a diaphragm tank?
Both separate the air charge from the water. A diaphragm tank, like the Flexcon Well-Rite, has a membrane fixed to the tank wall. A bladder tank holds the water in a bag that can be replaced on some composite tanks. Sizing, pre-charge and installation are the same; choose by capacity, material and price.
What size well pressure tank do I need?
Allow 1 gallon of drawdown per GPM of pump output, and remember drawdown is only 25 to 30 percent of the tank's volume. A 10 GPM pump needs a 33 to 44 gallon tank, such as the Well-Rite WR-120R or WR-140R. A bigger tank cycles the pump less and extends its life.
Can I replace an air over water pressure tank with a pre-charged tank?
Yes. Choose a pre-charged diaphragm tank with the same connection size and at least the same drawdown, fit it with a union tank tee, and set the pre-charge 2 PSI below the switch cut-in. The old air volume control and snifter valve are no longer needed.
How do pre-charged pressure tanks enhance water system efficiency?
Pre-charged tanks, such as the Flexcon Well-Rite and Red Lion, come with a factory-set air charge, reducing the need for manual adjustments and ensuring optimal water drawdown. This results in fewer pump cycles and improved energy efficiency.